- 55 -
WA
LL
MOUN
TED
AOY
G
09-
14LZ
CAN
11. Safety devices
Type of
protection
Protection form
Model
AOYG09LZCAN AOYG12LZCAN AOYG14LZCAN
Circuit protection
Current fuse (Near the terminal)
250 V, 20 A
250 V, 5 A
250 V, 5 A
Current fuse (Filter PCB)
—
250 V, 20 A
250 V, 5 A
Current fuse (Main PCB)
250 V, 15 A
250 V, 5 A
250 V, 3.15 A
250 V, 3.15 A
Fan motor
protection
Thermal protection
program
Activate
110±15 °C
Fan motor stop
Reset
95±10 °C
Fan motor restart
Compressor
protection
Thermal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart