- 32 -
W
A
LL
MOU
N
TED
ASYG09-14LZCA
9) Indoor unit fan control for energy saving for cooling
Enables or disables the power-saving function by controlling the indoor unit fan rotation when the
outdoor unit is stopped during cooling operation.
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the setting
on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low speed.
Function number
Setting value
Setting description
Factory setting
49
00
Disable
01
Enable
♦