3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢
Fan speed
Indoor fan speed is defined as below.
Operation mode
Fan mode
Speed (rpm)
ASYG09KHCA
ASYG12KHCA
ASYG14KHCA
Heating
POWERFUL
1,320
1,370
HIGH
1,100
1,210
MED+
1,040
1,140
MED
940
1,040
LOW
820
880
QUIET
600
740
Cool air prevention
600
600
S-LOW
540
540
Cooling/Fan
POWERFUL
1,320
1,370
HIGH
1,100
1,210
MED
940
1,040
LOW
820
880
QUIET
600
680
Soft quiet
540*
1
600*
1
S-LOW
540*
2
540*
2
Dry
X zone: 600
J zone: 600
X zone: 680
J zone: 640
*1: Fan mode only
*2: Cooling mode only
¢
Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.