1-5. Compressor frequency limitation by outdoor temperature
The minimum compressor frequency is limited by outdoor temperature as below.
•
Cooling/Dry mode
F zone
38°C
E zone
19°C
D zone
10°C
C zone
B zone
A zone
0°C
-10°C
Model name
Outdoor temperature zone
Limitation of compressor
frequency
AOYG09KHCAN
AOYG12KHCAN
AOYG14KHCAN
A zone
18 rps
B zone
18 rps
C zone
18 rps
D zone
1 rps
E zone
1 rps
F zone
22 rps
•
Heating mode
F zone
19°C
E zone
5°C
D zone
0°C
C zone
B zone
A zone
-15°C
-25°C
Model name
Outdoor temperature zone
Limitation of compressor
frequency
AOYG09KHCAN
AOYG12KHCAN
AOYG14KHCAN
A zone
39 rps
B zone
39 rps
C zone
17 rps
D zone
10 rps
E zone
1 rps
F zone
1 rps
1-5. Compressor frequency limitation by outdoor temperature