- (01 - 02) -
WA
L
L
M
O
U
N
T
E
D
T
Y
P
E
AST
G
0
9
-1
2
K
M
C
A
WA
L
L
M
O
U
N
T
E
D
T
Y
P
E
AST
G
0
9
-1
2
K
M
C
A
Energy saving control
Human sensor catches movements of people in a room, and operates with lower capacity when the room
is empty. When people come back to the room, it automatically returns to the previous operating mode.
10°C HEAT operation
*Only available with Wireless RC.
The room temperature can be set to go no lower than 10 °C,
thus ensuring that the room does not get too cold when not occupied
NOTE:
When the room temperature is higher than 10 °C, “
•
10°C HEAT
” operation will not start. Operation starts and maintains the room
temperature at 10 °C when the temperature drops below 10 °C.
Economy operation
Example : Cooling operation
Te
mp.
Economy operation
Shift
setting
temp
Control maximum current
Normal operation
Time
Set temperature
Low outdoor air temperature correspondence
Corresponds to cooling operation at 10 °C outdoor air temperature
Corresponds to heating operation at -15 °C outdoor air temperature
Cooling
Heating
10
to
46
°C
-15
to
24
°C
Demand Control
Restricts the operation of air-conditioner based on the demand from
energy providers in order to cut the peak load.
10
°C
20
°C
“10°C HEAT”
Button
ON
Indoor unit
operation
START
Economy operation is energy saving, as the set
•
temperature of indoor unit is shifted by 1 °C and
the maximum electric value of the outdoor unit is
suppressed.
Energy saving operation by detecting someone’s movement
Human
sensor