Communication error
(indoor unit remote controller)
Communication error
(indoor unit outdoor unit)
Room temperature sensor open
AUTO
TIMER
MODE
START/STOP
CLOCK ADJUST
SET TIME
TEMP./DAY
FAN
CONTROL
MASTER
CONTROL
2
1
AUTO
DEFROST TEST
SET
ZONE
DAY OFF
ENERGY SAVE
If there is a problem with the air conditioner, it will stop run-
ning and “EE: EE” will be displayed instead of the clock.
(1) If the operation lamp is on then press the START/
STOP button to turn it off.
(2) Press the SET TIME (
▼
) and the TEMP./DAY (
▼
)
buttons at the same time for more than three seconds
to start the self diagnosis check.
An error code will be displayed in the clock display area.
(3) Press the SET TIME (
▼
) and the TEMP./DAY (
▼
) buttons
again for more than three seconds to end the self diag-
nosis check.
ERRORS AND SELF DIAGNOSIS
Room temperature sensor shortcircuited
Indoor heat exchanger temperature
sensor open
Indoor heat exchanger temperature
sensor shortcircuited
Outdoor heat exchanger temperature
sensor open
Outdoor heat exchanger temperature
sensor shortcircuited
Power source connection error
Float switch operated
Outdoor temperature sensor open
Outdoor temperature sensor
shortcircuited
Discharge pipe temperature sensor open
Discharge pipe temperature sensor
shortcircuited
Outdoor high pressure abnormal
Discharge pipe temperature abnormal
Model abnormal
Indoor fan abnormal
Outdoor signal abnormal
Outdoor EEPROM abnormal
Error Code
Error Code
s
t
s
t
Error contents
TROUBLESHOOTING
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-
trical breaker, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker to ensure that power is completely off.
Before requesting service, perform the following checks:
WARNING!
Symptom
Doesn’t operate immedi-
ately:
Problem
●
If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.
●
Whenever the electrical breaker is turned off then on again, the
protection circuit will operate for about 3 minutes, preventing unit
operation during that period.