6.1. Wiring system diagram
Connection cable to outdoor unit or BRANCH BOX
INDOOR UNIT
OUTDOOR UNIT or
BRANCH BOX
TERMINAL
Type 60245 IEC57
Cable size 1.5 mm
2
(Inter-unit)
Power lines
Grounding line
Power line
Control line
Please connect it to
the specified terminal.
Wired remote controller cable
*Ground the remote controller
(Please connect it when necessary.)
Red
White
Black
Indoor
unit side
CAUTION
Tighten the indoor unit connection cable and power supply indoor and outdoor unit,
branch box terminal board connections firmly with the terminal board screws. Faulty
connection may cause a fire.
If the indoor unit connection cable and power supply are wired incorrectly, the air
conditioner may be damaged.
Connect the indoor unit connection cable by matching the numbers of the outdoor,
branch box and indoor units terminal board numbers as shown in terminal label.
Earth both the indoor and outdoor, branch box units by attaching a earth cable.
Unit shall be grounded in compliance with the applicable local and national cables.
CAUTION
Be sure to refer to the above diagram for do correct field wiring. Wrong wiring causes
malfunction of the unit.
Check local electrical rules and also any specific wiring instructions or limitation.
6.2. Connection cable preparation
Keep the earth wire longer than the other wires.
Power supply cable
or connection cable
20
mm
30mm
or
more
Earth wire
• Use a 4-core wire cable.
6.3. Connection of wiring
(1) Remove the control box cover from the control box.
Screw
Control box cover
Remove the 4 screws
and remove the control
box cover from the
control box.
(2) Cable connection
• C
onnect the connection cable to the terminal board.
• Connect the remote controller cable to the terminal board.
• Fix the remote controller cable to the control box cover with a nylon clamp.
Remote controller cable
1: Red
2: White
3: Black
Earth
Binder (Medium)
(Accessories)
Power supply cable
Binder (Medium)
(Accessories)
Remote controller cable
Power supply cable