Trouble shooting 26
Forecast of Cause :
Trouble shooting 27
Forecast of Cause:
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
MPa MPa
Abnormal noise
1. Abnormal installation (Indoor/ Outdoor)
2. Fan failure (Indoor/ Outdoor)
3. Compressor failure (Outdoor)
Diagnosis method when Abnormal noise is occurred
Abnormal noise is coming from Indoor unit.
(Check and correct followings)
Abnormal noise is coming from outdoor unit.
(Check and correct followings)
Is fan broken or deformed?
Is the screw of fan loose?
Is there any object which obstruct the fan rotation?
Is Main unit installed in stable condition?
Is the installation of air suction grille and
front panel normal?
Is fan broken or deformed?
Is the screw of Fan loose?
Is there any object which obstruct the fan rotation?
Is Main unit installed in stable condition?
Is fan guard installed normally?
Check if vibration noise by loose bolt or contact noise
of piping is happening.
Is Compressor locked?
>> Check Compressor (PARTS INFORMATION 1,2)
Water leaking
1. Erroneous installation 2. Drain hose failure
Diagnosis method when water is spitting out.
Is the filter clogged?
Check gas pressure and correct it
if there was a gas leak.
Diagnosis method when water leak occurs
Is Drain hose connection loose?
Is there a trap in drain hose?
Is drain hose clogged?
Is Main unit installed in stable condition?
Is Main unit broken or deformed at the time of
transportation or maintenance?
Is fan rotating?
02-28
Summary of Contents for AOCG040LBTA
Page 3: ...R410A SLIM DUCT type INVERTER 1 DESCRIPTION OF EACH CONTROL OPERATION ...
Page 26: ...2 TROUBLE SHOOTING R410A SLIM DUCT type INVERTER ...
Page 59: ...3 APPENDING DATA SLIM DUCT type INVERTER R410A ...
Page 67: ...3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan Jun 2016 Printed in Japan ...