background image

En-8

7.3.3. Wiring method

The wiring example for RB units ,outdoor units and indoor units is shown in the 

fi

 gure. 

L N

L N

L N

L N

Breaker

Breaker

Power 
supply

Power 
supply

Outdoor unit

Transmission

IN/U

IN/U

RB unit

RB unit

Indoor unit

Indoor unit

Indoor unit

Indoor unit

Indoor unit

(Cooling only)

Refrigerant piping

Refrigerant piping

Power supply 
230V 1  50Hz

Power supply 
230V 1  50Hz

Transmission

Transmission

Transmission

Transmission

Transmission

The transmission cable connects indoor units belonging to the same 
RB group. The transmission cable cannot be used to connect indoor units 
belonging to different RB groups.

GOOD

PROHIBITED

Refrigerant pipe

RB group 1

RB group 1

RB group 2

RB group 2

Transmission line

Transmission line

L N

L N

L N

L N

L N

L N

Crossover wiring of power supply

RB unit

RB unit

:Pull box

Power 
supply

Power 
supply

Power 
supply

Breaker

Power supply 
230V 1ø 50Hz

RB unit

RB unit

Power 
supply

GOOD

PROHIBITED

Transmission line

RB group

RB group

Transmission line

Refrigerant pipe

If using the indoor unit as a dedicated room cooling device, connect the 
transmission terminal of the indoor unit to the "OUT/RB" terminal of RB unit or 
outdoor unit transmission terminal.

9366249047-03_IM.indb   Sec1:8

9366249047-03_IM.indb   Sec1:8

2015/3/10   14:27:48

2015/3/10   14:27:48

Summary of Contents for Airstage UTP-RX01AH

Page 1: ...NSTALLAZIONE UNITÀ REFRIGERANTE SECONDARIA A uso esclusivo del personale tecnico autorizzato Ελληνικά Português ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ ΜΟΝΆΔΑ ΔΙΑΚΛΆΔΩΣΗΣ ΨΥΚΤΙΚΟΎ Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό MANUAL DE INSTALAÇÃO UNIDADE DE DERIVAÇÃO DE REFRIGERANTE Apenas para técnicos autorizados Русский Türkçe РУКОВОДСТВО ПО УСТАНОВКЕ МОДУЛЬ ВЕТКИ ОХЛАЖДЕНИЯ Только для авторизованного обслуживающ...

Page 2: ...rectly grounded and the supply line must be equipped with a dif ferential breaker in order to protect the persons The units are not explosion proof and therefore should not be installed in explosive atmosphere Do not turn on the power until all installation work is complete This unit contains no user serviceable parts Always consult authorized service per sonnel to repairs When moving consult auth...

Page 3: ...or connectable indoor units refer to the catalogue or the Design Technical manual 4 PIPING SPECIFICATIONS For details of piping specifications refer to the outdoor unit installation manual 5 INSTALLATION WORK 5 1 Selecting an installation location WARNING Take into consideration whether the place you install the main unit can fully with stand its weight For hanger bolts use embedded inserts or emb...

Page 4: ...33 18 22 147 172 298 147 89 Unit mm Top side A B C 198 155 124 206 48 75 198 268 30 Indoor unit side Outdoor unit side 400 400 100 Unit mm service access Service access A C B Outdoor unit side 500 or more 500 or more 20 or more 20 or more Ceiling hanging Installation limit Unit mm 5 2 2 Wall hanging 333 18 15 198 268 198 7 Unit mm service space grille 20 or more Installation limit 20 or more 300 o...

Page 5: ... Control box Control box cover Cable clamp 6 Change the control box attachment position 7 Attach the cable clamp ac cessory Thereafter put the cable in the cable clamp 8 Fix the control box position 4 screws 9 Attach Cover B to Cover A 1 screw 10 Attach Cover A 4 screws 11 Attach the control box cover 2 screws 5 7 Installation of the unit WARNING Perform installation in a location which can proper...

Page 6: ... ø12 7 1 2 Reducer 5 6 7 1 8 0 9 0 ø15 88 5 8 Reducer ø12 7 1 2 ø15 88 5 8 Reducer 11 2 12 5 14 0 ø19 05 3 4 ø12 7 1 2 ø19 05 3 4 18 0 ø19 05 3 4 ø15 88 5 8 Reducer ø19 05 3 4 Table 3 Connection pipe selection for when 2 to 8 indoor units are connected Total capacity of indoor unit kW Suction gas pipe mm in Discharge gas pipe mm in Gas pipe mm in 4 4 to 11 1 ø15 88 5 8 Reducer ø12 7 1 2 ø15 88 5 8...

Page 7: ...n Locally purchased Cable tie Locally purchased RB Unit 7 ELECTRICAL WIRING 7 1 Safety precautions for electrical wiring WARNING Electrical work must be performed in accordance with this Manual by a person certified under the national or regional regulations Be sure to use a dedicated circuit for the unit An insufficient power supply circuit or improperly performed electrical work can cause seriou...

Page 8: ...ly and transmission cable Recommended cable size mm2 Cable type Remark Power supply cable 2 5 Type60245 IEC57 or equivalent 1ø 50 Hz 198 to 264 V 2 Cable earth ground Transmission cable 0 33 LONWORKS compatible cable 22 AWG LEVEL 4 NEMA non polar 2 core twisted pair solid core diameter 0 65 mm 7 3 Wiring 7 3 1 Power supply cable Keep the ground cable longer than the other cables 20 mm Power supply...

Page 9: ...cable cannot be used to connect indoor units belonging to different RB groups GOOD PROHIBITED Refrigerant pipe RB group 1 RB group 1 RB group 2 RB group 2 Transmission line Transmission line L N L N L N L N L N L N Crossover wiring of power supply RB unit RB unit Pull box Power supply Power supply Power supply Breaker Power supply 230V 1ø 50Hz RB unit RB unit Power supply GOOD PROHIBITED Transmiss...

Page 10: ...ddress Manual address setting Setting example 2 RB AD 10 RB AD 1 Automatic address setting Set this switch to 00 at factory setting 0 to 63 Refrigerant circuit address Manual address setting Setting example 63 REF AD 10 REF AD 1 Automatic address setting Set this switch to 00 at factory setting 0 to 99 For details of automatic address setting please refer to the outdoor unit installation manual 8 ...

Page 11: ...OOLING HEATING PRIORITY FUNCTION Edge input only Connector Input signal Command CNA01 or CNA02 OFF ON Heating priority ON OFF Cooling priority CNA01 or CNA02 Priority mode Heating On Off Cooling 10 TEST RUN 10 1 Test run using Outdoor unit PC board Refer to the Installation Manual for the outdoor unit to perform the test run using the outdoor unit 10 2 Test run using Remote Controller Refer to the...

Reviews: