Operating procedure for check run
CAUTION
Initiate check run after more than 12 hours after the power supply is connected.
NOTE:
Be sure that the indoor unit and outdoor unit are not operating before starting the check
run.
1. Press the "CHECK" switch for 3 seconds or more.
2
W
S
CHECK
2. The number of indoor units (and the places) connected through the communication lines is
displayed.
• If the displayed number of units (places) and the installed number of units (places) is the
same, proceed to step 3.
• If the displayed number of units (places) and the installed number of units (places) is not
the same, shut off the power and check whether the indoor and outdoor communication
lines are properly connected.
• If there is no operation for 1 minute, the LED will return to the original display. (POWER/
MODE LED: ON)
Example: When 4 indoor units (A to D) are connected
F
E
D
C
MONITOR
ERROR
B
A
POWER
MODE
(2-blink)
3. Press the "CHECK" switch for 3 seconds or more again. Check run is initiated.
• When check run is initiated, all LEDs from A to F will flash. (Preliminary operation)
• The LED for each indoor unit will switch off in order as check for each unit is completed.
NOTE:
To interrupt the check run, press the "CHECK" switch.
Example: When 4 indoor units (A to D) are connected
(2-blink)
F
E
D
C
MONITOR
ERROR
B
A
POWER
MODE
DESIGN & TECHNICAL MANUAL
- 404 -
OUTDOOR UNIT
AOYG45LBLA6
Summary of Contents for agyg09lvca
Page 8: ......
Page 54: ... Models ASYG18LFCA ASYG24LFCA and ASYG24LFCC 46 MULTI TYPE 5 6 ROOMS TYPE ...
Page 55: ...4 5 Floor Ceiling type Models ABYG14LVTA and ABYG18LVTB 47 MULTI TYPE 5 6 ROOMS TYPE ...
Page 56: ...4 6 Floor type Models AGYG09LVCA AGYG12LVCA and AGYG14LVCA 48 MULTI TYPE 5 6 ROOMS TYPE ...
Page 281: ...Part 2 OUTDOOR UNIT 5 ROOMS TYPE MULTI TYPE AOYG36LBLA5 ...
Page 289: ...5 Wiring diagram 5 1 Model AOYG36LBLA5 281 OUTDOOR UNIT AOYG36LBLA5 ...
Page 352: ... 344 OUTDOOR UNIT AOYG36LBLA5 ...
Page 353: ...Part 3 OUTDOOR UNIT 6 ROOMS TYPE MULTI TYPE AOYG45LBLA6 ...
Page 360: ...5 Wiring diagram 5 1 Model AOYG45LBLA6 352 OUTDOOR UNIT AOYG45LBLA6 ...