5. HEATING OPERATION (Auto : Heating)
01-07
3. COOLING OPERATION (Auto : Cooling)
( Fig.5 : Airflow change - over ( Cooling : AUTO ) )
When the room
temperature rises
When the room
temperature drops
TR : Room temperature
Ts : Setting temperature
TR-Ts > - 1.5 degC
=
- 2.5 degC > TR-Ts
- 1.5 degC > TR-Ts > - 2.5 degC
=
TR-Ts > 2 degC
=
1 degC > TR-Ts
2 degC > TR-Ts > 1 degC
=
TR-Ts > 2.5 degC
=
1.5 degC > TR-Ts
2.5 degC > TR-Ts > 1.5 degC
=
TR-Ts > - 1 degC
=
- 2 degC > TR-Ts
- 1 degC > TR-Ts > - 2 degC
=
High mode
Med mode
Low mode
( Fig.7 : Airflow change - over ( Heating : AUTO ) )
When the room
temperature rises
When the room
temperature drops
TR : Room temperature
Ts : Setting temperature
Low mode
Med mode
High mode
Switch the airflow [AUTO], and the indoor fan motor will run according to a room temperature,
as shown in Figure 5.
On the other hand, if switched in [HIGH] [QUIET], the indoor motor will run at a constant airflow of [COOL]
operation modes QUIET, LOW, MED, HIGH, as shown in Table 5.
Switch the airflow [AUTO], and the indoor fan motor will run according to a room temperature,
as shown in Figure 7.
On the other hand, if switched [HIGH] [QUIET], the indoor motor will run at a constant airflow of [HEAT]
operation modes QUIET, LOW, MED, HIGH, as shown in Table 5.
4. DRY OPERATION (Auto : Dry)
During the dry operation, the fan speed setting can not be changed,it operates automatically as shown in Figure 6.
Room temperature variation which the room temperature sensor of the indoor unit body has detected.
Compressor
ON
OFF
Indoor fan
Dry air flow
S-Lo
OFF
( Fig.6 : Indoor Fan Control )
10
30
60
180
60
180
60 10
30
(SEC)