5.  SELECTING THE MOUNTING POSITION

Decide the mounting position with the customer as follows:

5.1. Indoor unit

(1)  Install the indoor unit level on a strong wall which is not subject to vibration.
(2)  The inlet and outlet ports should not be obstructed: the air should be able to blow all 

over the room.

(3)  Install the unit a dedicated electrical branch circuit.
(4)  Do not install the unit where it will be exposed to direct sunlight.
(5)  Install the unit where connection to the outdoor unit or branch box is easy.
(6)  Install the unit where the drain pipe can be easily installed.
(7)  Take servicing, etc. into consideration and leave the spaces shown in “6.1. Installation 

dimensions”. Also install the unit where the 

fi

 lter can be removed.

Correct initial installation location is important because it is dif

fi

 cult to move unit after it is 

installed.

 WARNING

 Select installation locations that can properly support the weight of the indoor. Install the 
units securely so that they do not topple or fall.

 CAUTION

Do not install the unit in the following areas:
•  Area with high salt content, such as at the seaside. It will deteriorate metal parts, causing the parts 

to fail or the unit to leak water.

•  Area 

fi

 lled with mineral oil or containing a large amount of splashed oil or steam, such as a 

kitchen. 
It will deteriorate plastic parts, causing the parts to fail or the unit to leak water.

•  Area that generates substances that adversely affect the equipment, such as sulfuric gas, chlorine 

gas, acid, or alkali. 
It will cause the copper pipes and brazed joints to corrode, which can cause refrigerant leakage.

•  Area that can cause combustible gas to leak, contains suspended carbon 

fi

 bers or 

fl

 ammable 

dust, or volatile in

fl

 ammables such as paint thinner or gasoline.

• If gas leaks and settles around the unit, it can cause a 

fi

 re.

•  Area where animals may urinate on the unit or ammonia may be generated.

 Do not use the unit for special purposes, such as storing food, raising animals, growing 
plants, or preserving precision devices or art objects.
It can degrade the quality of the preserved or stored objects.

 Do not install where there is the danger of combustible gas leakage.

 Do not install the unit near a source of heat, steam, or 

fl

 ammable gas.

 Install the unit where drainage does not cause any trouble.

Install the indoor unit, outdoor unit, branch box, power supply cable, transmission cable, 
and remote control cable at least 1 m away from a television or radio receivers. The 
purpose of this is to prevent TV reception interference or radio noise.
 (Even if they are installed more than 1 m apart, you could still receive noise under some 
signal conditions.)

 If children under 10 years old may approach the unit, take preventive measures so that 
they cannot reach the unit.

 Install the indoor unit on the wall where the height from the 

fl

 oors more than 1.8 m.

6. INSTALLATION WORK

6.1. Installation dimensions

110 mm or over **

1.5 m or over 

Remote 

controller

Remote controller 

holder

Tapping screw 

(small)

1.8 m or over

(Wall cap)

120 mm or over *

Wall hook 

bracket

110 mm or over **

*    The distance between the wall hook bracket and the ceiling 

should be 120 mm or more.

**  The side next to the sidewall must follow the size indicated in the 

figure.

6.2. Indoor unit piping direction

The piping can be connected in the 6 directions indicated in the following.
When the piping is connected in direction (2) , (3) , (4) or (5) , cut along the piping groove 
in the side of the under cover with a hacksaw.

(Rear)

(2)  Right 

outlet

(5)  Left 

outlet

(6)  Left rear 

outlet

(3) Right bottom outlet

(1) Right rear outlet

(4)  Left bottom outlet

6.3. Under cover removal

(1) Remove the screw caps and screws from the 

under cover (in each of 3 places).

(2) Lift up the central part of the under cover.
(3) Release the tabs by pressing on the side of the 

under cover (in 2 places on the side).

(4) Remove the under cover while turning it.

(1)

(1)

(1)

Under cover

Screw cap

Screw

(4)

(4)

(3)

(2)

6.4. Under cover installation

(1) Push the tabs on the side of the under cover into 

the base (in 2 places on the side).

(2) Press in the top parts of the triangle markings on      

the under cover (in 2 places).

(3) Attach the screws (in 3 places).
(4) Attach the screw caps (in 3 places).

(1)

(1)

(1)

(2)

(2)

6.5. Cutting the knockout hole

Cutting the knockout hole for piping on under cover:
The piping can be connected in the 6 directions indicated in the following. 
When the piping is connected in direction (2), (3), (4) or (5), use a cutting tool to cut along 
the groove for the piping that will coming out of the under cover.

For (5) Left outlet

For (4) Left bottom outlet

For (3) Right bottom outlet

For (2) Right outlet

9319357003-02_IM_EN.indd   3

9319357003-02_IM_EN.indd   3

7/27/2011   3:40:48 PM

7/27/2011   3:40:48 PM

Summary of Contents for 9319357003-02

Page 1: ...r autorisiertes Personal MANUEL D INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION MANUAL AIR CONDITIONER INDOOR UNIT Compact Wall Mounted Type PART NO 9319357003 02...

Page 2: ... the power always wait 5 minutes before touching electrical components This unit contains no user serviceable parts Always consult authorized service person nel to repairs When moving consult authorized service personnel for disconnection and installation of the unit 2 ABOUT THE UNIT 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as conventional ref...

Page 3: ...utput port Communication kit UTY TWBXF For the installation of optional parts Optional communication kit is necessary for the installation 3 GENERAL SPECIFICATION This installation manual briefly outlines where and how to install the air conditioning system Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system ...

Page 4: ...ear a source of heat steam or flammable gas Install the unit where drainage does not cause any trouble Install the indoor unit outdoor unit branch box power supply cable transmission cable and remote control cable at least 1 m away from a television or radio receivers The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 1 m apart you could...

Page 5: ...serting be sure not to attach any material besides water If any other material is attached it will cause deterioration and water leakage After removing drain hose be sure not to forget mounting drain cap Be sure to fix the drain hose with tape to the bottom of piping Prevent drain water freezing under low temperature environment When installing indoor unit s drain hose outdoors necessary measure f...

Page 6: ... table for flaring with R410A flare tools to achieve the specified flaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm 6 35 1 4 17 9 52 3 8 22 12 70 1 2 26 15 88 5 8 29 19 05 3 4 36 6 9 2 Bending pipes If pipes are shaped by hand be careful not to collapse them Do not bend the pipes in an angle more than 90 When...

Page 7: ... when wiring cable When stripping off the insulation of a lead wire always use a special tool such as a wire stripper If there is no special tool available carefully strip the insulation with a knife etc 1 Use crimp type terminals with insulating sleeves as shown in the figure below to con nect to the terminal block 2 Securely clamp the crimp type terminals to the wires using an appropriate tool s...

Page 8: ...pipe heat insulation and indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap For left and left rear piping butt the connection pipe heat insulation and indoor unit pipe heat insulation together and bind them with and vinyl tape so that there is no gap For left and left rear piping wrap the area which accommodates the rear piping housing section with cloth tape Fo...

Page 9: ...ditioner operation 2 Press the MODE button and the FAN button simultaneously for 2 seconds or more to start the test run Test run display 3 Press the start stop button to stop the test run 11 REMOTE CONTROLLER INSTALLATION CAUTION Check that the indoor unit correctly receives the signal from the remote controller then install the remote controller holder Select the remote controller holder selecti...

Page 10: ...hite Black Black Insulated connection Connector 3 0 m m 3 5 4 5 m m 7 0 8 0 m m Installing the wired remote controller terminal sold separately Connect the wired remote controller terminal to the connector CNC01 on the relay control board Relay wire Connector CNC01 Wired remote controller cord Rib 12 1 Accessories Communication kit The following installation accessories are supplied Use them as re...

Page 11: ...epending on the installed environment the room temperature sensor may require a cor rection The settings may be selected as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 30 00 Slightly lower control 01 Lower control 02 Warmer control 03 Function number Setting value Installing the external connect kit terminal sold separately Connect the wire o...

Page 12: ...ensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error Heating Room Temperature Correction Depending on the installed environment the room temperature sensor may require a cor rection The settings may be changed as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 31 00 Lower control 01 Slightly warmer control 02 Warmer control...

Page 13: ...ion detection error 9 7 Outdoor unit fan motor error 9 9 4 way valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator lamp green TIMER indicator lamp orange ECONOMY indica...