En-10

14. FUNCTION SETTING

Perform the “FUNCTION SETTING” according to the installation conditions using the 
remote controller.

 CAUTION

Con

fi

 rm whether the wiring work for outdoor unit has been 

fi

 nished.

 Con

fi

 rm that the cover for the electrical enclosure on the outdoor unit is in place.

•  This procedure changes to the function settings used to control the indoor unit according 

to the installation conditions. Incorrect settings can cause the indoor unit to malfunction.

•  After the power is turned on, perform the “FUNCTION SETTING” according to the 

installation conditions using the remote controller.

•  The settings may be selected between the following two: Function Number or Setting Value.
•  Settings will not be changed if invalid numbers or setting values are selected.
•  Refer to the installation manual enclosed with the remote control unit when the wired 

remote control unit (option) is used.

•  Adjust the signal code of the indoor unit and the signal code of the remote controller.

Entering the Function Setting Mode

While pressing the POWERFUL button and SET TEMP. ( ) simultaneously, press the 
RESET button to enter the function setting mode.

Selecting the Function Number and Setting Value

(1)  

Press the SET TEMP. (

 / 

) buttons to select 

the function number. (Press the 10°C HEAT button 
to switch between the left and right digits.)

(2)  

Press the POWERFUL button to proceed to setting 
the value. (Press the POWERFUL button again to 
return to the function number selection.)

(3)  

Press the SET TEMP. (

 / 

) buttons to select 

the setting value. (Press the 10°C HEAT button to 
switch between the left and right digits.)

(4)  

Press the MODE button, in the order listed to con

fi

 rm 

the settings.
Please con

fi

 rm that the beep sounds.

(5)  

Next, please press START/STOP (

) button.

Please con

fi

 rm that the beep sounds.

(6)  

Press the RESET button to cancel the function set-
ting mode.

(7)  

After completing the FUNCTION SETTING, be sure to turn off the power and turn it 
on again.

 CAUTION

After turning off the power, wait 10 seconds or more before turning on it again.
The Function Setting does not become active unless the power is turned off then on 
again.

 
Filter Sign

The indoor unit has a sign to inform the user that it is time to clean the 

fi

 lter. Select the 

time setting for the 

fi

 lter sign display interval in the table below according to the amount of 

dust or debris in the room. If you do not wish the 

fi

 lter sign to be displayed, select the set-

ting value for “No indication”.

(

...  Factory setting)

Setting Description 

Function 

Number

Setting Value

Standard (400 hours)

11

00

Long interval (1,000 hours)

01

Short interval (200 hours)

02

No indication

03

Cooling Room Temperature Correction

 Depending on the installed environment, the room temperature sensor may require a cor-
rection. 
The settings may be selected as shown in the table below.

(

...  Factory setting)

Setting Description 

Function 

Number

Setting Value

Standard

30

00

Slightly lower control

01

Lower control

02

Warmer control

03

Function number

Setting 

value

Installing the external connect kit terminal (sold separately)

Connect the wire of external input/output to the board of external connect kit.

(

EXTERNAL INPUT CONNECT TO NO. CNA01
EXTERNAL OUTPUT CONNECT TO NO. CNB01, CNB02

)

External
connect kit cord

Error Status Output 
connector : CNB02 (Black connector)

Operation Status Output 
connector : CNB01 (White connector)

Control Input 
(Operation/Stop or Forced stop) 
connector : CNA01 (White connector)

Rib

Fixing the wires

After connecting the terminals, thread the wires through the notches and clasp 
of the control box as circled on the 

fi

 gure below.

Then 

fi

 x the wires onto the control box with the provided binder.

Relay control board

Binder

12.2.5. Installing the control box, connector and the control cover

 (1)  Attach the control box to the indoor unit.
 (2)  Connect the connector wires.
 (3)  Attach the control cover.
 (4)  Attach the 3 screws. Screw 2 is the screw which installs the ground wire.

12.2.6. Labelling

Paste the wiring label beside the label for schematic diagram inside the front panel.

12.2.7. Installing the front panel and intake grille

(Refer to 9.2. intake grille installation and 9.4. front panel installation)

13. SELECTING THE REMOTE CONTROLLER SIGNAL CODE

When two or more air conditioners are installed in a room and the remote controller is op-
erating an air conditioner other than the one you wish to set, change the signal code of the 
remote controller to operate only the air conditioner you wish to set (4 selections possible).
When two or more air conditioners are installed in a room, please contact your retailer to 
set the individual air conditioner signal codes.

Selecting the Remote Controller Signal Code

Use the following steps to select the signal code of the remote controller. (Note that the 
air conditioner cannot receive a signal code if the air conditioner has not been set for the 
signal code.)

(1)   Press the START/STOP (

) button until only the clock 

is displayed on the remote controller display.

(2)   Press the MODE button for at least 5 seconds to display 

the current signal code (initially set to  ).

(3)   Press the SET TEMP. (  / 

) buttons to change the 

signal code between 

Match the code on the display to the air conditioner 
signal code.

(4)   Press the MODE button again to return to the clock 

display. The signal code will be changed.

•  If no buttons are pressed within 30 seconds after the signal code is displayed, the 

system returns to the original clock display. In this case, start again from step 1.

• The air conditioner signal code is set to A prior to shipment.

9319357003-02_IM_EN.indd   10

9319357003-02_IM_EN.indd   10

7/27/2011   3:43:24 PM

7/27/2011   3:43:24 PM

Summary of Contents for 9319357003-02

Page 1: ...r autorisiertes Personal MANUEL D INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION MANUAL AIR CONDITIONER INDOOR UNIT Compact Wall Mounted Type PART NO 9319357003 02...

Page 2: ... the power always wait 5 minutes before touching electrical components This unit contains no user serviceable parts Always consult authorized service person nel to repairs When moving consult authorized service personnel for disconnection and installation of the unit 2 ABOUT THE UNIT 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as conventional ref...

Page 3: ...utput port Communication kit UTY TWBXF For the installation of optional parts Optional communication kit is necessary for the installation 3 GENERAL SPECIFICATION This installation manual briefly outlines where and how to install the air conditioning system Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system ...

Page 4: ...ear a source of heat steam or flammable gas Install the unit where drainage does not cause any trouble Install the indoor unit outdoor unit branch box power supply cable transmission cable and remote control cable at least 1 m away from a television or radio receivers The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 1 m apart you could...

Page 5: ...serting be sure not to attach any material besides water If any other material is attached it will cause deterioration and water leakage After removing drain hose be sure not to forget mounting drain cap Be sure to fix the drain hose with tape to the bottom of piping Prevent drain water freezing under low temperature environment When installing indoor unit s drain hose outdoors necessary measure f...

Page 6: ... table for flaring with R410A flare tools to achieve the specified flaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm 6 35 1 4 17 9 52 3 8 22 12 70 1 2 26 15 88 5 8 29 19 05 3 4 36 6 9 2 Bending pipes If pipes are shaped by hand be careful not to collapse them Do not bend the pipes in an angle more than 90 When...

Page 7: ... when wiring cable When stripping off the insulation of a lead wire always use a special tool such as a wire stripper If there is no special tool available carefully strip the insulation with a knife etc 1 Use crimp type terminals with insulating sleeves as shown in the figure below to con nect to the terminal block 2 Securely clamp the crimp type terminals to the wires using an appropriate tool s...

Page 8: ...pipe heat insulation and indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap For left and left rear piping butt the connection pipe heat insulation and indoor unit pipe heat insulation together and bind them with and vinyl tape so that there is no gap For left and left rear piping wrap the area which accommodates the rear piping housing section with cloth tape Fo...

Page 9: ...ditioner operation 2 Press the MODE button and the FAN button simultaneously for 2 seconds or more to start the test run Test run display 3 Press the start stop button to stop the test run 11 REMOTE CONTROLLER INSTALLATION CAUTION Check that the indoor unit correctly receives the signal from the remote controller then install the remote controller holder Select the remote controller holder selecti...

Page 10: ...hite Black Black Insulated connection Connector 3 0 m m 3 5 4 5 m m 7 0 8 0 m m Installing the wired remote controller terminal sold separately Connect the wired remote controller terminal to the connector CNC01 on the relay control board Relay wire Connector CNC01 Wired remote controller cord Rib 12 1 Accessories Communication kit The following installation accessories are supplied Use them as re...

Page 11: ...epending on the installed environment the room temperature sensor may require a cor rection The settings may be selected as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 30 00 Slightly lower control 01 Lower control 02 Warmer control 03 Function number Setting value Installing the external connect kit terminal sold separately Connect the wire o...

Page 12: ...ensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error Heating Room Temperature Correction Depending on the installed environment the room temperature sensor may require a cor rection The settings may be changed as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 31 00 Lower control 01 Slightly warmer control 02 Warmer control...

Page 13: ...ion detection error 9 7 Outdoor unit fan motor error 9 9 4 way valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator lamp green TIMER indicator lamp orange ECONOMY indica...

Reviews: