En-8

9.4. Front panel installation

(1) First, 

fi

 t the lower part of the front panel, and insert top and bottom hooks. (2 top 

sides, 7 bottom sides, 2 center)

Indoor unit

Bottom holes

(3 position)

Bottom hooks

(3 position)

Bottom holes

(4 position)

Center holes

(2 position)

Center hooks

(2 position)

Top hooks

(2 position)

Top holes

(2 position)

Indoor unit

Front panel

Bottom hooks

(2 position)

Bottom hooks
(2 position)

Front panel

(2) Attach the 4 screws.
(3) Attach the wire cover. (Attach the 1 screw.)
(4) Attach the intake grille.

 CAUTION

Install the Front panel and Intake grille securely. If installation is imperfect, the Front 
panel or Intake grille may fall off and cause injury.

10. TEST  RUN

Check items

(1)  Is operation of each button on the remote controller unit normal?

(2)  Does each lamp light normally?

(3) Do 

air

fl

 ow direction louvers operate normally?

(4)  Is the drain normal?

(5)  Do not have an abnormal noise and vibration during operation?

 

Do not operate the air conditioner in test run for a long time.

[Operation method]

  For the operation method, refer to the operating manual.

   The outdoor unit, may not operate, depending on the room temperature. In this case, 

keep on pressing the MANUAL AUTO button of the indoor unit for more than 10 

seconds. The OPERATION indicator lamp (green) and TIMER indicator lamp (orange) 

will begin to 

fl

 ash simultaneously during cooling test run. Then, heating test run will 

begin in about 3 minutes when HEAT is selected by the remote control operation. (Please 

follow the operating manual for remote control operation.)

(When the air conditioner is running by pressing the test run button, the OPERATION 

indicator lamp and TIMER indicator lamp will simultaneously 

fl

 ash slowly.)

Press and hold MANUAL AUTO 
button for 10 seconds

MANUAL AUTO button

 

When ending the test run, keep on pressing the MANUAL AUTO button of the indoor 

unit for more than 3 seconds.

[Using the wired remote controller] (Option)

For the operation method, refer to the operating manual.
(1)  Stop the air conditioner operation.
(2)  Press the MODE button and the FAN button simultaneously for 

2 seconds or more to start the test run.

Test run display

(3)  Press the start/stop button to stop the test run.

11.  REMOTE CONTROLLER INSTALLATION

 CAUTION

Check that the indoor unit correctly receives the signal from the remote controller, 
then install the remote controller holder.
Select the remote controller holder selection site by paying careful attention to the fol-
lowing:
Avoid places in direct sunlight.
Select a place that will not be affected by the heat from a stove, etc.

11.1.  Remote controller holder installation

  Install the remote controller a maximum  distance of 6 m  from the remote control signal 

receiver. However, when installing the remote controller, check that it operates cor-
rectly.

  Install the remote controller holder to a wall, pillar, etc. with the tapping screw.

Remote controller 
holder 

fi

 xing

Remote controller 
mounting

Remote controller 
holder

Tapping 
screw 
(small)

(1) Set

Remote 
controller

(2) Down

12. OPTIONAL KIT INSTALLATION (UTY-TWBXF)

This air conditioner can be connected with the following optional kits.
 •  Wired remote controller
 •  Simple remote controller
 •  External connect kit

BEFORE INSTALL WIRED REMOTE CONTROLLER

 •  When you use wired remote controller, some functions may not be used.

 CAUTION

Before installing, be sure to disconnect all power supply.

Don’t touch the heat exchanger.

During installing or removing operation, be sure not to have wire caught by parts or 
draw it hard. Or it may result troubles to the air-conditioner.

Avoid place in direct sunlight.

Select place that will not be affected by the heat from a stove, etc

 Before setting up the optional kit, please con

fi

rm whether air-conditioner can receive 

the signal.

Do not connect the wired remote controller to the terminal for power supply.

 When connecting the wired remote controller with the indoor unit, use the connecting 
cable (supplied with wired remote controller or simple remote controller).

 Recommended cable length of wired remote controller is 10 m. Make sure to do insu-
late of connecting part when extended the cable.

Do not connect power supply with the terminal.

INDOOR UNIT

PCB

TERMINAL

9319357003-02_IM_EN.indd   8

9319357003-02_IM_EN.indd   8

7/27/2011   3:42:49 PM

7/27/2011   3:42:49 PM

Summary of Contents for 9319357003-02

Page 1: ...r autorisiertes Personal MANUEL D INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION MANUAL AIR CONDITIONER INDOOR UNIT Compact Wall Mounted Type PART NO 9319357003 02...

Page 2: ... the power always wait 5 minutes before touching electrical components This unit contains no user serviceable parts Always consult authorized service person nel to repairs When moving consult authorized service personnel for disconnection and installation of the unit 2 ABOUT THE UNIT 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as conventional ref...

Page 3: ...utput port Communication kit UTY TWBXF For the installation of optional parts Optional communication kit is necessary for the installation 3 GENERAL SPECIFICATION This installation manual briefly outlines where and how to install the air conditioning system Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system ...

Page 4: ...ear a source of heat steam or flammable gas Install the unit where drainage does not cause any trouble Install the indoor unit outdoor unit branch box power supply cable transmission cable and remote control cable at least 1 m away from a television or radio receivers The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 1 m apart you could...

Page 5: ...serting be sure not to attach any material besides water If any other material is attached it will cause deterioration and water leakage After removing drain hose be sure not to forget mounting drain cap Be sure to fix the drain hose with tape to the bottom of piping Prevent drain water freezing under low temperature environment When installing indoor unit s drain hose outdoors necessary measure f...

Page 6: ... table for flaring with R410A flare tools to achieve the specified flaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm 6 35 1 4 17 9 52 3 8 22 12 70 1 2 26 15 88 5 8 29 19 05 3 4 36 6 9 2 Bending pipes If pipes are shaped by hand be careful not to collapse them Do not bend the pipes in an angle more than 90 When...

Page 7: ... when wiring cable When stripping off the insulation of a lead wire always use a special tool such as a wire stripper If there is no special tool available carefully strip the insulation with a knife etc 1 Use crimp type terminals with insulating sleeves as shown in the figure below to con nect to the terminal block 2 Securely clamp the crimp type terminals to the wires using an appropriate tool s...

Page 8: ...pipe heat insulation and indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap For left and left rear piping butt the connection pipe heat insulation and indoor unit pipe heat insulation together and bind them with and vinyl tape so that there is no gap For left and left rear piping wrap the area which accommodates the rear piping housing section with cloth tape Fo...

Page 9: ...ditioner operation 2 Press the MODE button and the FAN button simultaneously for 2 seconds or more to start the test run Test run display 3 Press the start stop button to stop the test run 11 REMOTE CONTROLLER INSTALLATION CAUTION Check that the indoor unit correctly receives the signal from the remote controller then install the remote controller holder Select the remote controller holder selecti...

Page 10: ...hite Black Black Insulated connection Connector 3 0 m m 3 5 4 5 m m 7 0 8 0 m m Installing the wired remote controller terminal sold separately Connect the wired remote controller terminal to the connector CNC01 on the relay control board Relay wire Connector CNC01 Wired remote controller cord Rib 12 1 Accessories Communication kit The following installation accessories are supplied Use them as re...

Page 11: ...epending on the installed environment the room temperature sensor may require a cor rection The settings may be selected as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 30 00 Slightly lower control 01 Lower control 02 Warmer control 03 Function number Setting value Installing the external connect kit terminal sold separately Connect the wire o...

Page 12: ...ensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error Heating Room Temperature Correction Depending on the installed environment the room temperature sensor may require a cor rection The settings may be changed as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 31 00 Lower control 01 Slightly warmer control 02 Warmer control...

Page 13: ...ion detection error 9 7 Outdoor unit fan motor error 9 9 4 way valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator lamp green TIMER indicator lamp orange ECONOMY indica...

Reviews: