70S_Rev1
67
Heater Menu
Select Heater Mode
Each tube-heating mode is optimized for a type of Fujikura protection sleeve. These modes
can be found in database area for reference. Copy the appropriate one and paste it to the
user-programmable area. The operator can edit the user-programmable modes.
Data Base
Parameter
Description
60mmS
FP-03
For standard 60mm protection sleeve,
Such as Fujikura FP-03 or FP-03M protection sleeves.
40mmS
FP-03(L=40)
For standard 60mm protection sleeve,
Such as Fujikura FP-03(40mm) or FP-03M protection sleeves.
Note : Cleave length 8mm.
40mmR
FP-04T
For standard 40mm protection sleeves,
Such as Fujikura FP-03 (L=40).
15mmS
FPS01-400-15
For 400 or less um of diameters of coating and splice of the
interference length of 5 mm or less
20mmS
FPS01-900-20
For 900 or less um of diameters of coating and splice of the
interference length of 6 mm or less
60mmS
FPS01-DC-60
For Splice of a drops cable.
28mmS
FC-SC-**-30/20
For Fuse connect splice.
45mmS
FC-SC-**-09
The dimensions of the Protection Sleeve after shrink
Form
Tension
member
Sleeve
length
Prepare fiber
length
Diameter of an
adaptation
optical fiber
Diameter
of a result
FP-03
SUS
60mm
16mm or less 250~900um
3.1mm
FP-03(40mm)
SUS
40mm
10mm or less
250~900um
3.1mm
FP-04T
Glass Ceramic 40mm
10mm or less
250~900um
4.0mm
FPS01-400-15 SUS
15mm
5mm or less
~400um
1.5mm
FPS01-900-20 SUS
20mm
6mm or less
~900um
2.3mm
* The dimensions of the protection sleeve after shrink vary depending on the
diameter of the fiber.
Sleeve length *
Outer tube
Inner tube
Tension member