70S_Rev1
24
Basic Operation
Change of the Operation Mode
Selection of the operation mode
Each operation mode consists of parameters shown below so that operation of the equipment
after the end of work can be set up.
The extraction work of a fiber can be smoothly done by working by changing the operation
mode according to the contents of work.
MENU key is pressed on the [READY] screen; a [Splice Menu] screen will be displayed.
The Down key is pressed, [Splice Settings] is chosen and the ENT key is pressed.
Parameter
Description
Operation Mode
Auto-L
Proof test, wind-protector opening, and sheath clamp opening are
automatically performed after the end of splicing.
There is the mode of the left, the right, and right and left according to the
patulous state of a sheath clamp.
Auto-R
Auto-LR
Fast
Wind-Protector opening and a proof test are simultaneously done after the
end of connection.
Perform sheath clamp opening manually.
Normal
If the SET key is pressed after the end of splice, wind-protector opening and
a proof test will be carried out.
Perform sheath clamp opening manually.
Manual
All the parameters in custom-made mode are in the state of OFF.
Customized
Sheath Clamp Auto Release
Setup of the "left", the "right", "right and left", and "OFF" can be performed.
Auto Start Trigger
Select of the "OFF", the "Fiber Set", "Cover Close", and "OFF" can be
performed.
Proof Auto Start
Setup of the "ON" and "OFF" can be performed.
Cover Close Reaction Time
Time after a fiber is set until wind-protector closes can be set up.