Service Manual for FNDX 5
08/2009 FR
10.1.1 FILTER SYSTEM FOR DEVELOPER
10.1.2
HOW TO REPLACE THE FILTER INSERT
1.
Switch off the processor using the
2.
Open the closing sheet
Main power switch
CAUTION:
To change the filter cartridge it is
necessary that the filter system
is fixed on the main frame.
NOTE:
Mount the side panel to the processor
and fix it with the mounting screws.
During working, the filter has to be installed inside the processor.
If you want to change/replace the filter insert, mount the filter on the frame like in the pictures.