background image

 

Preface 

Thank you for purchasing our OPC-LM1-PS1 inverter option card. Before using the option card, read this manual carefully 
to understand how to use the option card correctly. Improper handling blocks correct operation or causes a short life or 
breakdown. This manual does not describe how to use the inverter. Refer to the FRENIC-Lift Instruction Manual for details 
about the inverter. Keep this manual on hand for reference when using the option card. 
 
 

Safety Precautions 

Note the following items when using the option card. Improper use may result in unexpected failure, electric shock, or 
possible injury. 
 

(1) Application 

WARNING

 

  This product must not be used for any life support system or other purpose directly related to human safety. 

 Although this product is manufactured under strict quality control, be sure to install appropriate safety devices for 

applications where drive failure could result in serious accident or material loss. 

An accident could occur.

 

 

(2) Installation and Wiring

 

WARNING

 

  Wait at least five minutes after turning off the power before installing or wiring the option card. 

Use a circuit tester or similar instrument to check the voltage before performing installation or wiring. 
(Check whether the charge lamp goes off.) 

Otherwise, electric shock may occur.

 

  Discharge statistic electricity from your body before handling the option card. Never touch the option card with wet 

hands; 

otherwise, accident or electric shock may occur.

 

  No foreign matter such as screws, metal patches, lint, chips, and dust in the option card. 

There is risk of fire or accident.

 

  Do not damage or stress the wiring; 

otherwise, accident or electric shock may occur. 

  Do not connect the reducer between the motor and the encoder.

 

There is a risk of accident.

 

 

CAUTION

 

  Do not install or operate a damaged option card or one that is lacking parts; 

otherwise, an injury may occur. 

  Since noise is generated by the inverter, motor, and wiring, carefully monitor surrounding sensors and devices for 

abnormal operation. 

There is a risk of accident.

 

 
 

(3) Operation

 

WARNING

 

  Check and adjust parameters before operation. Improper parameters may cause an unexpected action for some 

machines. 

There is a risk of accident.

 

 

CAUTION

 

  High-speed operation can be set easily for the inverter. Fully check motor or device performance before changing the 

setup;

 otherwise, accident may occur.

 

 
 
(4) Maintenance and Inspection, and Parts Replacement

 

WARNING

 

  Wait at least five minutes after turning off the power before inspecting the option card. (Check whether the charge lamp 

goes off.) 

There is a risk of electric shock.

 

  Only authorized personnel are allowed to maintain and inspect the option card and replace parts; 

otherwise, electric 

shock or injury may occur.

 

  Never modify the option card; 

otherwise, electric shock or injury may occur.

 

 

CAUTION

 

  Do not execute a megger test (insulation resistance measurement). 

 
 

(5) Discard 

CAUTION 

 

  Since the option card uses soldering lead, treat it as an industrial waste when discarding it. 

Summary of Contents for OPC-LM1-PS1

Page 1: ...lly operate the equipment Read this instruction manual and understand the description before installing connecting wiring operating or performing maintenance and inspection of the option Keep this ins...

Page 2: ...card with wet hands otherwise accident or electric shock may occur No foreign matter such as screws metal patches lint chips and dust in the option card There is risk of fire or accident Do not damag...

Page 3: ...Terminal Function and Specifications 8 2 5 Control Specifications 8 3 Applicable Encoder 9 3 1 Specifications of Applicable Encoder 9 3 2 Encoder Installation and Signal 9 4 Wiring 10 4 1 Wiring Leng...

Page 4: ...etails refer to the Multi function Keypad Instruction Manual INR SI47 1092 E Use the FRENIC Loader option for the FRENIC Lift and click the System monitor tab on the Operation Status Monitor window Fo...

Page 5: ...G Turn off the power and wait for at least five minutes before starting installation Further check that the LED monitor is unlit and check that the DC link bus voltage between the P and N terminals is...

Page 6: ...the four spacers and CN1 on the back of the OPC LM1 PS1 into the spacer holes and connector CN1 on the control circuit board in the inverter Visually check that the spacers and CN1 are firmly inserted...

Page 7: ...m2 or less per year 86 to 106 kPa in storage Atmospheric pressure 70 to 106 kPa during transportation 1 Assuming a comparatively short storage period e g during transportation or the like 2 Even if th...

Page 8: ...he inverter must not be subjected to sudden changes in temperature that will cause condensation to form Altitude 1 000 m max Note Vibration 3 mm Max amplitude 2 to 9 Hz 9 8 m s2 9 to 20 Hz 2 m s 2 20...

Page 9: ...put frequency Max 50 kHz Differential input signal PA PA PB PB 0 6V to 1 2V CK Communication clock non inverting CK Communication clock inverting Clock transmission DT Communication data non inverting...

Page 10: ...oder Encoder power supply Encoder model HEIDENHAIN ECN1313 or its equivalent 3 2 Encoder Installation and Signal The encoder shall rotate in the direction shown in Figure 3 1 when terminal FWD is ON E...

Page 11: ...is 10 m or more PA green black A PA yellow black A PB blue black B PB red black B CK purple CLOCK CK yellow CLOCK DT gray DATA DT pink DATA Wiring of the option card and the encoder The wiring of the...

Page 12: ...coder in the specification voltage of encoder There is a risk of failure L1 R L2 S L3 T U V W M CK DT DT FRN LM1S G OPC LM1 PS1 PA PB PB CK PO PA PO CM CM Encoder FPA FPB CM CM User Controller Figure...

Page 13: ...oder L36 ASR P Constant at high speed 2 0 It is necessary to adjust L38 ASR P Constant at low speed 2 0 It is necessary to adjust 5 2 Procedure of Magnetic Pole Position Offset Tuning You have to exec...

Page 14: ...the FWD key starts tuning The EXECUTING is displayed on the monitor of the MFKP during the tuning The EXECUTING disappears indicating that it is the end of tuning The L03 data automatically returns to...

Page 15: ...3 2 Adjust the following parameters to eliminate vibration and the rollback becomes small The following table shows the tendency to the phenomenon by setting of the parameter Function Code Code Settin...

Page 16: ...ed inverter unbalanced load compensation works correctly Using analog speed command Time 0 ON FWD Release Brake Reference speed pre ramp Lift controller output F24 F23 Time 0 Reference speed final Act...