– 19 –
●
Timer Code
(Note1) Available only for DO2
* Other than the alarm setting, each of the event output functions can be assigned to DO1 to
3.
For more details on each of the event output functions, refer to
"
7-12. Digital output
"
-
"
1.
DO event setting
"
(page 14).
12
Model Specifications
12-1
PXG4 Standard Model List
Note 1:
If output 1 was for current or voltage output, option cannot be assigned to CT1.
(If 7th digit was assigned to G or J, 5th digit cannot be assigned to E nor P.)
Note 2:
If output 2 was for relay contact, SSR drive, current, voltage or retransmission output, 3
digital outputs cannot be assigned.
(If 6th digit was assigned to A, C, E, P, R or S, 9th digit cannot be assigned to M.)
Note 3:
If CT1 was selected in option 1, none in <Digital output> cannot be assigned.
(If 7th digit was assigned to G or J, 9th digit cannot be assigned to 0.)
Note 4:
If RSV1 in option 1 and digital input 1 were selected simultaneously, output 2 cannot be
asssigned.
(If 7th digit was assigned to F or 2, 6th digit cannot be assigned to A, C, E, P, R nor S.)
Zone alarm
24
High/Low absolute alarm
25
High/Low deviation alarm
26
High absolute/Low
deviation alarm
27
High deviation/Low
absolute alarm
28
High/Low absolute alarm
(with hold)
29
High/Low deviation alarm
(with hold)
30
High absolute/Low
deviation alarm (with hold)
31
High deviation/Low
absolute alarm (with hold)
Type
DO1 to DO3
Alarm Type
Action diagram
Timer
32
ON delay timer
33
OFF delay timer
34
ON/OFF delay timer
Point
What is alarm with hold?
The alarm will not turn ON immediately when the process value gets into
the alarm band and enters again. If without hold, alarm may turn ON when
starting up.
Caution
•
When alarm action code is changed, alarm set value may also become dif-
ferent from previous settings.
•
When alarm action type code is changed, turn off the power once, and
then re-start the controller, before starting control.
•
Aln: AL1 to AL3 show the alarm set values
•
ALnh: AL1h to AL3h show the alarm set values
•
ALnL: AL1L to AL3L show the alarm set values
•
dLYn: dLY1 to dLY3 show the alarm delay on set values
Type
DO1 to DO3
Alarm Type
Action diagram
PV
t
ALnh
ALnL
SV
PV
t
ALnh
ALnL
SV
PV
t
ALnL
ALnh
SV
PV
t
ALnL
ALnh
PV
t
ALnh
ALnL
SV
PV
t
ALnh
ALnL
SV
PV
t
ALnL
ALnh
SV
PV
t
ALnL
ALnh
DI
ALM
dLYn
DI
ALM
dLYn
DI
ALM
dLYn
dLYn
PV (process value)
power on
lower limit alarm
lower limit alarm
(with hold)
power on
power off
Lower limit alarm
output area
off
off
off
on
on
off
off
on
Digit Specifications
1 2 3 4 5 6 7 8
-
9 10 11 12 13 - 14 Notes
4
<Size of front WxH>
48 x 48 mm
P X G 4
5
<Output 1>
Relay contacts
A
SSR drive
C
Current (0 to 20mA DC / 4 to 20mA DC)
E
Note 1
Voltage (0 to 5V DC / 1 to 5V DC /
0 to 10V DC / 2 to 10V DC)
P
Note 1
6
<Output 2>
None
Y
Relay contacts
A
Note 2,4
SSR drive
C
Note 2,4
Current (0 to 20mA DC / 4 to 20mA DC)
E
Note 2,4
Voltage (0 to 5V DC / 1 to 5V DC /
0 to 10V DC)
P
Note 2,4
Re-transmission output current
(0 to 20mA DC / 4 to 20mA DC)
R
Note 2,4
Re-transmission output voltage
(0 to 5V DC / 1 to 5V DC /
0 to 10V DC / 2 to 10V DC)
S
Note 2,4
7
<Option 1>
None
Y
RS485
M
Digital input (No. 1) + digital input
(No. 2)
T
Digital input (No. 1) + RSV1
H
Digital input (No. 1) + CT1
G
Note 1,3
RS 485 + digital input (No. 1)
V
RS 485 + RSV1
K
RS 485 + CT1
J
Note 1,3
RS 485 + Digital input (No. 1)
+ RSV1
F
Note 4
Digital input (No. 1) + RSV1
+ Digital input (No. 2)
2
Note 4
8
<Revision symbols>
1
9
<Digital Output>
(Relay contact output)
None
0
Note3
Digital output 1 point (No.1)
1
Digital output 2 points (No.1, 2)
F
Digital output 3 points (No.1, 2, 3)
M
Note2
Digital output 2 points
[independent common] (No.1, 2)
J
10
<Power supply> < Instruction manual>
100V/240V AC no instruction manual
N
100V/240V AC English instruction manual
V
24V AC/DC no instruction manual
C
24V AC/DC English instruction manual
B
11
<Option 2>
None
Y
12
0
13
0