background image

– 19 – 

Timer Code

(Note1) Available only for DO2
* Other than the alarm setting, each of the event output functions can be assigned to DO1 to

3.
For more details on each of the event output functions, refer to 

"

7-12. Digital output

"

 - 

"

1.

DO event setting

"

 (page 14).

12

Model Specifications

12-1

PXG4 Standard Model List

Note 1:

If output 1 was for current or voltage output, option cannot be assigned to CT1.
(If 7th digit was assigned to G or J, 5th digit cannot be assigned to E nor P.)

Note 2:

If output 2 was for relay contact, SSR drive, current, voltage or retransmission output, 3 
digital outputs cannot be assigned.
(If 6th digit was assigned to A, C, E, P, R or S, 9th digit cannot be assigned to M.)

Note 3:

If CT1 was selected in option 1, none in <Digital output> cannot be assigned.
(If 7th digit was assigned to G or J, 9th digit cannot be assigned to 0.)

Note 4:

If RSV1 in option 1 and digital input 1 were selected simultaneously, output 2 cannot be 
asssigned.
(If 7th digit was assigned to F or 2, 6th digit cannot be assigned to A, C, E, P, R nor S.)

Zone alarm

24

High/Low absolute alarm

25

High/Low deviation alarm

26

High absolute/Low 
deviation alarm

27

High deviation/Low 
absolute alarm

28

High/Low absolute alarm 
(with hold)

29

High/Low deviation alarm 
(with hold)

30

High absolute/Low 
deviation alarm (with hold)

31

High deviation/Low 
absolute alarm (with hold)

Type

DO1 to DO3

Alarm Type

Action diagram

Timer

32

ON delay timer

33

OFF delay timer

34

ON/OFF delay timer

Point

What is alarm with hold?
The alarm will not turn ON immediately when the process value gets into
the  alarm band and enters again. If without hold, alarm may turn ON when
starting up.

Caution

When alarm action code is changed, alarm set value may also become dif-
ferent from previous settings.

When alarm action type code is changed, turn off the power once, and
then re-start the controller, before starting control.

Aln: AL1 to AL3 show the alarm set values

ALnh: AL1h to AL3h show the alarm set values

ALnL: AL1L to AL3L show the alarm set values

dLYn: dLY1 to dLY3 show the alarm delay on set values

Type

DO1 to DO3

Alarm Type

Action diagram

PV

t

ALnh

ALnL

SV

PV

t

ALnh
ALnL

SV

PV

t

ALnL

ALnh

SV

PV

t

ALnL

ALnh

PV

t

ALnh

ALnL

SV

PV

t

ALnh
ALnL

SV

PV

t

ALnL

ALnh

SV

PV

t

ALnL

ALnh

DI

ALM

dLYn

DI

ALM

dLYn

DI

ALM

dLYn

dLYn

PV (process value)

power on

lower limit alarm

lower limit alarm

 (with hold)

power on

power off

Lower limit alarm 
output area

off

off

off

on

on

off

off

on

Digit Specifications

1 2 3 4 5 6 7 8

-

9 10 11 12 13 - 14 Notes

4

<Size of front WxH>

48 x 48 mm

P X G 4

5

<Output 1>

Relay contacts

A

SSR drive

C

Current (0 to 20mA DC / 4 to 20mA DC)

E

Note 1

Voltage (0 to 5V DC / 1 to 5V DC / 
0 to 10V DC / 2 to 10V DC)

P

Note 1

6

<Output 2>

None

Y

Relay contacts

A

Note 2,4

SSR drive

C

Note 2,4

Current (0 to 20mA DC / 4 to 20mA DC)

E

Note 2,4

Voltage (0 to 5V DC / 1 to 5V DC / 
0 to 10V DC)

P

Note 2,4

Re-transmission output current 
(0 to 20mA DC / 4 to 20mA DC)

R

Note 2,4

Re-transmission output voltage 
(0 to 5V DC / 1 to 5V DC / 
0 to 10V DC / 2 to 10V DC)

S

Note 2,4

7

<Option 1>

None

Y

RS485

M

Digital input (No. 1) + digital input 
(No. 2)

T

Digital input (No. 1) + RSV1

H

Digital input (No. 1) + CT1

G

Note 1,3

RS 485 + digital input (No. 1)

V

RS 485 + RSV1

K

RS 485 + CT1

J

Note 1,3

RS 485 + Digital input (No. 1) 
+ RSV1

F

Note 4

Digital input (No. 1) + RSV1
+ Digital input (No. 2)

2

Note 4

8

<Revision symbols>

1

9

<Digital Output>
(Relay contact output)

None

0

Note3

Digital output 1 point (No.1)

1

Digital output 2 points (No.1, 2)

F

Digital output 3 points (No.1, 2, 3)

M

Note2

Digital output 2 points 
[independent common] (No.1, 2)

J

10

<Power supply> < Instruction manual>

100V/240V AC no instruction manual

N

100V/240V AC English instruction manual

V

24V AC/DC no instruction manual

C

24V AC/DC English instruction manual

B

11

<Option 2>

None

Y

12

0

13

0

Summary of Contents for Micro Controller X PXG4

Page 1: ...ed for continuous and safe use of this equipment Some parts installed on this equipment have a limited life and or may deteriorate with age The warranty period for this unit including accessories is o...

Page 2: ...auxiliary relay If the output operation frequency is high selecting a SSR SSC drive output type is recommended Proportionate cycles Relay output 30 seconds or more SSR SSC drive output 1 second or mo...

Page 3: ...ontroller move it as least 30 mm away Cautions when wiring Start by wiring from the left hand terminals terminals 1 to 6 Use a screw that is the right size on terminals and tighten them with a torque...

Page 4: ...ction 7 8 9 10 Relay output 13 14 Current output 13 14 SSR drive 3 4 14 13 Voltage output Control output 1 15 16 17 18 Thermocouple input 15 16 17 18 A B B Resistance bulb input 15 16 17 18 Current vo...

Page 5: ...lay and Status Display In monitor mode the PV display shows item names while the SV display shows the input out put values For more details on P P P PA A A AS S S SS S S S PASS see 5 6 Key Lock and Pa...

Page 6: ...E EF F F FE E E E FEFE is entered as P P P PA A A AS S S SS S S S PASS all of the channels OPE ch to DSP ch can be displayed and set This super password function is useful when you forget the set pass...

Page 7: ...d d d d7 7 7 7 d7 Differential time 7 Sets the differential time 0 0 to 999 9 sec 60 0 sec h h h hy y y yS S S S7 7 7 7 hyS7 ON OFF control hysteresis 7 Sets the hysteresis when using the ON OFF cont...

Page 8: ...5 Note1 r r r rt t t tF F F F rTF RSV input filter Sets the time constant for the RSV input filter 0 0 to 120 0 sec 0 0 sec Note1 fixed at 0 8bit PV input underflow 9bit PV input overflow 10bit underr...

Page 9: ...it2 non excitation output alarm function bit3 hold reset function RST S S S St t t tm m m md d d d STMd Start mode Sets the operation mode when starting up Auto auto mode startup Man manual mode start...

Page 10: ...et the PID parameter when using fuzzy control Setting fuzzy PID control 7 4 Self tuning Control Self tuning Control is a control which automatically calculate the value of PID under the condi tion tha...

Page 11: ...ontrol equipment power t SV process value control loop close close open PV Point Set the following parameters before running auto tuning PV input type PV input upper limit PV input lower limit Decimal...

Page 12: ...r r r r and set the ramp time 6 Display the soak time parameter t t t tm m m m1 1 1 1r r r r and set the soak time 7 Repeat steps 4 through 7 and set the remaining parameters MV MV1 MV2 MV1 MV2 MV lim...

Page 13: ...er DO2 Starts the specified timer for DO2 2 2 2 23 3 3 3 Start timer DO3 Starts the specified timer for DO3 2 2 2 24 4 4 4 No function Do not set 2 2 2 25 5 5 5 No function Do not set 2 2 2 26 6 6 6 S...

Page 14: ...ent 96 Time signal 26th segment 97 Time signal 27th segment 98 Time signal 28th segment 99 Time signal 29th segment 100 Time signal 30th segment 101 Time signal 31st segment 102 Time signal 32nd segme...

Page 15: ...aud rate setting parameter C C C Co o o oM M M M and choose 9600 bps even 9 9 9 96 6 6 6e e e ev v v v This sets the baud rate to 9600 bps and the parity to even 3 Display communication permissions S...

Page 16: ...value For dual control set S S S Sb b b bo o o o2 2 2 2 the same way 4 Press the key to set the value 1 Display the system menu S S S SY Y Y YS S S S C C C Ch h h h 7 7 7 7 2 Set both ramp SV decline...

Page 17: ...V No 1 Display the operation menu o o o oP P P PE E E E C C C Ch h h h 1 1 1 1 2 Display the selected PID number S S S Sv v v vn n n n and choose di 3 Display the di function setting d d d di i i i1 1...

Page 18: ...ent range C Measurement range F Smallest input increment C Input code Resistance bulb JIS IEC Pt 100 0 to 150 32 to 302 0 1 1 1 1 1 0 to 300 32 to 572 0 1 0 to 500 32 to 932 0 1 0 to 600 32 to 1112 1...

Page 19: ...code is changed turn off the power once and then re start the controller before starting control Aln AL1 to AL3 show the alarm set values ALnh AL1h to AL3h show the alarm set values ALnL AL1L to AL3L...

Page 20: ...Thermocouple input greatest one among 0 3 FS 1 digit and 1 C or 2 C Resistance bulb input greatest one among 0 3 FS 1 digit and 0 5 C mV input voltage input current input 0 3 FS 1digit Indication res...

Reviews: