8. Maintenance
The purpose of the maintenance and adjustment schedule is to keep the generator in the best
operating condition.
- Shut off the engine before performing any maintenance. If the engine must
be run, make sure the area is well ventilated. The exhaust contains
poisonous carbon monoxide gas.
- Use genuine parts or their equivalent. The use of replacement parts which
are not of equivalent quality may damage the generator.
E
300
very
year
or
hrs
(2)
(3)
(3)
E
6
100
very
month
or
hrs
E
3
50
very
month
or
hrs
F
10
irst
month
or
hrs
Each
use
Regular service period
Engine oil
Air cleaner
Spark plug
Spark arrester
Fuel sediment cup
Valve clearance
Fuel tank and strainer
Fuel line
Check
Change
Check
Clean
Clean-adjust
Clean
Check
Check-adjust
Clean
Check
Every 2 years (Replace if necessary)(3)
WARNING!
-
-
-
Log hours of operation to determine proper maintenance.
Service more frequently when used in dusty areas.
These items should be serviced by an authorized dealer, unless the owner has the proper tools and
is mechanically proficient.