4. Maintenance

-
-

-

- see

tab.1 and all electrical connecting

-

-

-

-

-

-

- see tab. 3

must be disposed of

The service life of the machine depends on maintenance quality.

PRIOR TO ANY OPERATION SET THE PRESSURE SWITCH TO THE OFF POSITION, PULL

OUT THE PLUG AND COMPLETELY DRAIN THE RESERVOIR.

Check that all screws (in particular those of the head of the unit) are tightly drawn up (fig. 9)

. The check must be carried out prior to the first compressor

starting.

Clean the suction filter according to the type of environment and in any case at least every 100

hours. If necessary, replace the filter (a clogged filter impairs efficiency while an inefficient filter
causes harsher wear on the compressor (figures 10a - 10b).

Change the oil after the first 100 hours of operation and subsequently every 300 hours. Check the

oil level periodically.

Never mix different grade oils. If the oil changes color (whitish = presence of water; dark =

overheated), it is good practice to replace the oil immediately.

After topping up, tighten the plug (fig. 11) making sure that there are no leaks during use. Once a

week, check the oil level to assure lubrication in time (fig. 6a).

Periodically (or after completing work if for more than an hour), drain the condensate that forms

inside the reservoir due to the humidity in the air (fig. 12) in order to protect the reservoir from rust
and so as not to restrict its capacity.

Periodically, check the tension of the belts (fig. 13)

.

* Spent oil and condensate

in compliance with protection of the environment

and current legislation.

Т

3

ABLE

- BELT DEFLECTION

MODEL

BELT

DEFLECTION

VALUE, mm

FORCE, kg

VCF/50 СM3

6

32 ~ 50

VCF/100 СМ3

6

32 ~ 50

B4000B/50 СМ3

6

32 ~ 50

B4000B/100 СМ3

6

32 ~ 50

B5200B/100 СТ4

6

36 ~ 54

B5200B/200 СТ4

6

36 ~ 54

B6800B/100 СТ5

6

41 ~ 59

B6800B/200 СТ5

6

41 ~ 59

B8800/270 CТ7,5

6

45 ~ 63

-
-

-

The value set can be checked on the gauge (for versions equipped with this, fig. 8).

Please check that the air consumption and the maximum working pressure of the pneumatic tool to

be used are compatible with the pressure set on the pressure regulator and with the amount of air
supplied by the compressor.

When you have finished working, stop the machine, pull out the plug and empty the reservoir.

Summary of Contents for B4000B/100 CM3

Page 1: ...VCF 50 3 VCF 100 3 B4000B 50 3 B4000B 100 3 B5200B 100 CT4 B5200B 200 CT4 B6800B 100 CT5 B6800B 200 CT5 B880Q 270 CT7 5...

Page 2: ...Before use read the handbook carefully Warning hot surfaces Obligatory eye protection Danger automatic control closed loop Dangerous voltage Power Tank capacity Air intake Max pressure Revolutions mi...

Page 3: ...O m perator s anual www fubag ru 2...

Page 4: ...www fubag ru O m perator s anual 3...

Page 5: ...www fubag ru O m perator s anual 4...

Page 6: ...www fubag ru O m perator s anual 5...

Page 7: ...with this Never switch off the compressor by pulling out the plug in order to avoid restart with pressure in the head Always use the handle to move the compressor When operating the compressor must b...

Page 8: ...ever use the compressor without guards belt guard and never touch moving parts To avoid overheating of the electric motor this compressor is designed for intermittent operation as indicated on the dat...

Page 9: ...essor continues to operate automatically with this work cycle until the position of the switch of the pressure switch figures 5a 5b 5c 5d is modified To use the compressor again wait at least 10 secon...

Page 10: ...After topping up tighten the plug fig 11 making sure that there are no leaks during use Once a week check the oil level to assure lubrication in time fig 6a Periodically or after completing work if fo...

Page 11: ...ician for operations on electric components cables motor pressure switch electric panel etc Any other type of operation must be carried out by authorized Service Centers requesting original parts Tamp...

Page 12: ...als of sales and ware receipt issued by salesman are subjects of warranty Within the warranty period the service center eliminate free of charge all detected production defects The manufacturer discla...

Page 13: ...www fubag ru FUBAG FUBAG 1 5 C 40 C 4 5 50 4 20 dB 2 1...

Page 14: ...www fubag ru 3 1...

Page 15: ...50 220 50 220 50 220 50 830 360 740 1050 420 850 830 360 720 1050 420 850 50 71 46 66 B5200B 100 CT4 B5200B 200 CT4 B6800B 100 CT5 B6800B 200 CT5 B8800 270 CT7 5 3 3 4 4 5 5 100 200 100 200 270 10 10...

Page 16: ...www fubag ru 15 3 10 1 3 6a 6b O 5a 5b 5c 5d 5a 5b 5c 2 4 5a 5b 5c 7 8...

Page 17: ...b 50 300 100 11 6a 12 3 DIN51562 Rimol VDL100 3 VCF 50 M3 6 32 50 VCF 100 3 6 32 50 B4000B 50 3 6 32 50 B4000B 100 3 6 32 50 B5200B 100 4 6 36 54 B5200B 200 4 6 36 54 B6800B 100 5 6 41 59 B6800B 200 5...

Page 18: ...www fubag ru 17 5...

Page 19: ...6 www fubag ru 18 7 12 5...

Page 20: ......

Reviews: