background image

15 | 

P a g e

 

 

Limitations of Security Products: Security products and alarm 
systems do not offer guaranteed protection against burglary, 
fire, or other emergencies.  They may fail to warn for diverse 
reasons,  including  (but  not  limited  to):  power  failure,  dead 
batteries,  improper  installation,  coverage  “blind  spots”, 
coverage  areas  overlooked  during  installation,  defeat  by 
technically  sophisticated  intruders,  component  failure,  or 
inadequate maintenance.  Alarm systems should  be checked 
weekly  to  ensure  that  all  devices  are  working  properly.    AN 
ALARM SYSTEM IS NOT A SUBSTITUTE FOR INSURANCE. 
FSK  Electronics  (Pty)  Ltd,  warrants  its  products  to  be  in 
conformance with its own plans and specifications and to be 
free from defects in materials and workmanship under normal 
use  and  service  for  twelve  months  from  the  date  of  original 
purchase.  Seller's  obligation  shall  be  limited  to  repairing  or 
replacing, at its option, free of charge for materials or labour, 
any  part  which  is  proved  not  in  compliance  with  Seller's 
specifications or proves defective in materials or workmanship 
under normal use and service. Seller shall have no obligation 
under  this  Limited  Warranty  or  otherwise  if  the  product  is 
altered  or  improperly  repaired  or  serviced  by  anyone  other 
than  Seller.  For  warranty  service,  return  transportation 
prepaid, to the manufacturer 
There  are  no  warranties,  expressed  or  implied,  of 
merchantability,  or  fitness  for  a  particular  purpose  or 
otherwise, which  extend  beyond the description on the face 
hereof.  In  no  case  shall  seller  be  liable  to  anyone  for  any 
consequential or incidental damages for breach of this or any 

Summary of Contents for Hawk

Page 1: ...installation operation manual ...

Page 2: ...OWER SUPPLY 5 CHECK AC 5 DRY CONTACTS INPUTS 5 CONTACT ID INPUTS 5 SERIAL PORT 6 SELECTING THE PANEL SERIAL PORT 7 APPENDIX A SERIAL INTERFACE 8 RHINO SERIAL INTERFACE 9 TEXECOM SERIAL INTERFACE 9 PARADOX SERIAL INTERFACE 10 PIMA SERIAL INTERFACE 12 IDS SERIAL INTERFACE 12 SPECIFICATIONS 13 LIMITED WARRANTEE 15 ...

Page 3: ...k has the option of a remote control receiver which can be used for remote panic functions FEATURES AND FUNCTIONS Contact ID Tip and Ring Telephone interface to all leading control panels Up to 999 zones and 99 partition reporting using the Fast FSK protocol 7 Hardwired inputs with positive trip negative trip or both Input 3 can be programmed to delay an alarm trigger if the panel has siren annunc...

Page 4: ...the panel Any account code can be programmed into the panel The transmitter will send its own account code The Hawk will send full Contact ID messages all codes partitions and zones using the Fast FSK protocol INSTALLATION Opening the Hawk Cover The plastic cover on the Hawk is opened by inserting a small flat screw driver into the two openings at the top of the cover Gently pull the top of the co...

Page 5: ...ONES 2 CAC 12V GND 3 5 1 6 7 RING 4 TIP PANEL DIALLER FROM BATTERY 12V DC AC FROM TRANSFORMER SECONDARY ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 RING ZONE 1 TIP HARDWIRED ZONES SERIAL DATA TO PANEL SERIAL DATA FROM PANEL PANEL GROUND ALARM PANEL SERIAL PORT TTL 5V LEVELS ...

Page 6: ...ct AC voltages between 10 and 24V The AC Failure and AC Restore signals have a programmable delay default 10 minutes in order to prevent false triggers Dry Contact Inputs The dry contact inputs can be used to detect alarms generated from the outputs of the Alarm Panel or from other sources If the external device generates the alarm by pulling the input to ground negative trigger the pull up jumper...

Page 7: ...UT FUNCTION DEFAULT TRIGGER 1 OPEN CLOSE BY KEYHOLDER 1 HIGH CLOSE LOW OPEN 2 PANIC HIGH 3 DELAYED ALARM HIGH 4 BURG ZONE 1 HIGH 5 BURG ZONE 2 HIGH 6 MEDICAL HIGH 7 FIRE HIGH The inputs can be factory programmed for your particular requirements Serial Port The Hawk can receive alarms from the following alarm panels on its serial port FSK Rhino alarm panels Texecom premier range Paradox E65 SP6000 ...

Page 8: ...utton successively until the green RUN lamp flashes the correct number of times indicating the serial mode selected RUN LAMP FLASHES SERIAL FORMAT 1 Pima 2 Paradox 3 Texecom 4 Rhino 5 IDS Repeat the process until the correct serial port format has been selected The Hawk will remember the setting TEST the operation of the radio with the panel after the serial port format has been selected ...

Page 9: ...ngeable The following adapter boards are available ALARM PANEL ADAPTER RHINO No adapter TEXECOM PREMIER Texecom IDS 5 pin IDS Texecom IDS 5 pin PARADOX Paradox 4 pin PIMA Pima 4 pin Hawk Serial Interface Cable GND BLACK 4 3 2 1 1 3 4 2 DATA FROM PANEL BLUE DATA TO PANEL GREEN MOLEX 2510 NOT USED 1 MOLEX 2510 NOT USED 1 WIRES ARE TWISTED TOGETHER WIRE LENGTH 3 0m ...

Page 10: ...DS Program the Hawk to use the Texecom Serial Alarm Interface DTMF Serial Interface Tab The Hawk is connected to COM1 on the Alarm Panel The following programming is required on the Texecom panel MENU 39 OPTION 3 ON DISABLE ONLINE PRINTING MENU 70 1 2 5 8 ON ENABLE COMMUNICATOR MENU 71 OPTION 3 ON DISABLE ONLINE PRINTING 0 TEL NO 22 YES 1 ACC CODE 3456 YES 2 PROTOCOL TYPE 4 CONTACT ID 3 DIALLER AT...

Page 11: ... MG5050 and SP6000 alarm panel serial ports Note that the Hawk will not send all the events such as trouble conditions if it is not factory programmed to do so PARADOX FSK ALWAYS SENT EVENT GROUP NO SUB GROUP NO DESCRIPTION 06 Non Reportable Event Telephone Line Trouble Comms Trouble 29 Arming with User 01 32 User Number Close by Keyholder 1 20 30 Special Arming 03 Partial Arming Partial Arming 31...

Page 12: ...mpered 01 32 Zone Number Fault Zone 1 to 32 YES 44 New Trouble 01 AC Failure AC Fail YES 02 Batt Fail Batt Low YES 04 Bell Current Overload Bell Trouble 05 Bell disconnected Bell Trouble YES 08 Fail To Communicate Tel 1 Fail to Report YES 09 Fail to Communicate Tel 2 Fail to Report YES 10 fail to Communicate Pager Fail to Report 11 fail to communicate voice Fail to Report 46 Bus wireless module ne...

Page 13: ...ipheral Trouble 53 Wireless Module Sup Trouble Peripheral Trouble 54 Wireless Module Sup Rest Peripheral Trouble 55 Wireless Module Tamper Trouble Peripheral Trouble 56 Wireless Module Tamper Rest Peripheral Trouble PIMA SERIAL INTERFACE Plug the adapter marked PIMA into the serial port on the Pima alarm panel Plug the other end into the Hawk serial port The Pima serial interface will send the sta...

Page 14: ...ency of Operation Lowband 135 to 156MHz Highband 155 to 175MHz Carrier Power 8W into 50E Frequency Error 1kHz 0 to 55 C Spurious Conducted Components 36 dBm 9kHZ to 1GHz 30 dBm 1GHz to 4GHz Adjacent Channel Power 60dB Frequency Deviation 2 5kHz 2kHz standard Transient Frequency Behaviour To ETSI 300 086 Electrical Power Requirements 13 2V DC Nominal 10 15V 35mA Standby 1 6A Transmitter Active Low ...

Page 15: ...fe but hand it in at an official collection point for recycling The on board battery also contains substances that may pollute the environment Always remove the battery before you discard and dispose of the battery at an official collection point for batteries Physical Dimensions 107x136x46mm without antenna Housing Plastic with steel insert for RF earthing Packaged Weight 300g Packaged Dimensions...

Page 16: ... defects in materials and workmanship under normal use and service for twelve months from the date of original purchase Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labour any part which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall ha...

Page 17: ...ur or that there will be no personal injury or property loss as a result Consequently seller shall have no liability for any personal injury property damage or other loss based on a claim the product failed to give any warning However if seller is held liable whether directly or indirectly for any loss or damage arising under this limited warranty or otherwise regardless of cause or origin seller ...

Page 18: ...www fsk co za 14 Richard Road Industria North Johannesburg South Africa T 27 0 11 477 2600 E sales fsk co za Innovative technology by FSK Electronics Call Center 0861 105 962 ...

Reviews: