13 |
P a g e
SPECIFICATIONS
Transmitter
Radio Performance tested to : ETSI 300-086
EMI Tested to
: ETSI EN 301
Safety to
: EN 60 950
Mode of Operation
: FM
Channel Spacing
: 12,5kHz
Power Requirements
: 35mA Standby, < 1.6A
Transmitter Active
Frequency of Operation
: Lowband 135 to 156MHz
: Highband 155 to 175MHz
Carrier Power
: > 8W into 50E
Frequency Error
: < 1kHz (0 to 55 °C)
Spurious Conducted Components : < -36 dBm (9kHZ to 1GHz)
< -30 dBm (1GHz to 4GHz)
Adjacent Channel Power
: < -60dB
Frequency Deviation
: < 2.5kHz (2kHz standard)
Transient Frequency Behaviour : To ETSI 300-086
Electrical
Power Requirements
: 13.2V DC Nominal (10 – 15V)
35mA Standby, < 1.6A
Transmitter Active
Low Voltage Alarm
: 10.5V
Environmental