15
FSI®
DAT® SERIES PNEUMATIC SHELTERS
All Shelters have full privacy zipper closure and full screen zipper closure slip in and out dirty entry/clean exit doors,
high pressure and low pressure inflation deflation valves and pressure relief valves based on size of unit as
detailed below, one high pressure compressed air inflation hose with SCBA adapter w. safety cord, tie down ropes
and D
-
rings to tie off to, 2 upper air vents, repair kit, manual, shelter carry sleeve/bag, and a hammer. All canopy
walls are velcro
’
d to the floor air berms for air lock, and reflective striping is found on the upper air vents above
entry and exit doors.
Units can attach to a second FSI shelter or shower, if so ordered and specified. Simply inflate
the unit and commence use in approx. 1
-
15 minutes (size of shelter dependent).
Every shelter with a width of over 11 ft.
-
regardless of length and overall
size offers a top center air berm
running the entire length of the unit at the roof line and secondary full center length air berms running on
either side of the main center berm approx. 18
-
24" off center.
FSI offers a total of five
8
”
-
12"
diameter
lateral roof support air berms
-
size of shelter dependent.
FSI shelters lead the industry in terms of weight/
snow bearing capabilities/strength.
Whatever the specification at hand FSI meets and exceeds herein.
Every FSI
®
DAT
®
series shelter comes complete with electric inflator/deflator, and high pressure compressed air
fill hose and universal high pressure scba fitting.
All units supplied w. no charge redundant features allowing for
-
hanging undress/redress kits etc. on the inlet and
outlet side; or for use as handles in the event a victim is in such need.
All DAT
®
series shelters available with cross and center divider curtains, side doors, extra windows, skylights,
HVAC/clothing ducts with ties, etc. as per published FSI literature/pricing/specs.
Multiple optional accessories available inclusive of air heaters, air coolers, elevation grids, waste water pumps, etc.
available. Visit
FSI Valves Quantity for different units 021616
PART NUMBER
INFLATE / DEFLATE VALVE
RELIEF VALVE
HIGH PRESSURE VALVE *
SHOWERS
DAT1010S
-
DAT2020S
-
DAT3030S
-
DAT2525S
1
1
1
DAT3535S
-
DAT3060S
-
DAT4070S
-
DAT4099S
2
1
2
SHELTERS / ISOLATION SHELTERS / FIELD HOSPITAL SHELTERS OF SAME SIZE
DAT3030
-
DAT3015
1
1
1
DAT3060
-
DAT3370
-
DAT4070
-
DAT5672
2
1
2
DAT6000
-
DAT6012
2
2
2
DAT7500
3
3
3
INFLATE / DEFLATE VALVE
HIGH PRESSURE VALVE *
RELIEF VALVE
* FSI supplied high pressure valve to
be filled with compressed air using
only FSI supplied high pressure air fill
hose with locking connector and
universal scba adapter."