MAINTENANCE /
REP
AIR
TROUBLESHOOTING
GETTING
ST
ARTED
8
OPERA
TION
INSTALLATION INSTRUCTIONS (CONTINUED)
Lubrication
Before operating compressor, ensure oil is filled
to the center of the sight gauge (see figure 4)
Using any other type of oil may shorten pump life
and damage valves.
Recommended Oil (2 Options)
FSC-1000A ISO-100 Premium Reciprocating
Compressor Lubricant
12 quart case part number FSC-1000A-12
1 quart part number FSC-1000A-1
For generic option use 10W30
Oil Capacity
Approximately 8.5 oz.
Remove cap from oil fill opening. Install breather (found in parts
bag with this manual). Check oil level. See specification label on
compressor pump for the proper oil capacity and oil type.
All lubricated compressor pumps discharge some condensed water
and oil with the compressed air. Install appropriate water/oil removal
equipment and controls as necessary for the intended application.
Do not sure regular automotive oil. Additives in regular motor oil can
cause valve deposits and reduce pump life. For maximum pump life,
drain and replace oil after 50 hours of use.
OPERATING INSTRUCTIONS
All lubricated compressor pumps discharge some condensed water
and oil with the compressed air. Install appropriate water/oil removal
equipment and controls as necessary for the
intended application.
Failure to install appropriate water/oil removal equipment may
result in damage to machinery or workpiece.
Start-up/Break-in Procedure
Risk of Personal Injury. Do not attach air tools to open end of the hose until starting up is completed
and the unit checks okay.
Risk of Personal Injury. Never disconnect threaded joints with pressure in tank!
1. Check oil level per the Lubrication Section of this manual.
2. Open the bottom tank drain valve (See Figure 5) Turn outlet valve to open air flow.
3. Plug unit in.
4. Move pressure switch lever or knob to the
AUTO
position to run the unit. (See Figure 6)
5. Run the unit for 30 minutes at zero (0) psi (under no load) to break in pump parts.
6. Move the pressure switch lever or knob to
OFF
and turn tank drain valve to shut off air flow. The compressor is now ready for use.
7. Change oil after fi rst fi fty (50) hours of operation. Then perform oil changes every three (3) months.
ASSEMBL
Y
/
INST
ALLA
TION
SAFETY
/
SPECIFICA
TIONS
Oil Fill Area
Oil Drain Plug
Figure 4 - Lubrication
Sight Gauge
Full
Low