Frymaster YUM K3000 Operation Manual Download Page 21

 

2-4 

PROBLEM 

PROBABLE CAUSES 

CORRECTIVE ACTION 

Controller displays 

OIL IN DRAIN 

PAN / CONFIRM 

Drain valve open or possibility that 
oil is in drain pan. 

Press 

 (CONFIRM) and follow directions for 

FILL VAT FROM DRAIN PAN.

  

Controller displays 

FLT DYLD

 

A filter cycle has been delayed. 

This is a normal display when a filter has been 
delayed.  After the next filter prompt press 
YES to filter. 

Controller displays 

POL DYLD

 

A polish cycle has been delayed. 

This is a normal display when a polish has 
been delayed.  After the next polish prompt 
press YES. 

 
2.2.3   Error Log Codes

 

  

Code 

ERROR MESSAGE 

EXPLANATION 

E03 

ERROR TEMP PROBE FAILURE 

Temp probe reading out of range 

E04 

HI 2 BAD 

High limit reading is out of range. 

E05 

HOT HI 1 

High limit temperature is past more than 410

°

(210

°

C), or in CE countries, 395

°

F (202

°

C) 

E06 

HEATING FAILURE 

A component has failed such as controller, interface 
board, contactor, gas valve, ignition module or 
open-high limit. 

E20 

INVALID CODE LOCATION 

SD card removed during update 

E21 

FILTER PAPER PROCEDURE ERROR 
(Change Filter Paper) 

24 hour timer has expired 

E22 

OIL IN PAN ERROR 

Oil may be present in the filter pan. 

E25 

RECOVERY FAULT 

Recovery time exceeded maximum time limit. 

E28 

HIGH TEMP ALARM 

Oil has exceeded 40 ºF (4ºC) over setpoint. 

 

 
2.2.4   HP Pressure Fryer Specific 
 

The HP pressure fryer has a STRATIFY mode that turns the pump on for various times to mix the 
oil so that excess water can escape from the oil. 
 
It enters STRATIFY mode when: 

-The fryer reaches 300F (149C) after initially heating.  
-Every 30 minutes after cooks. 
-After an EXIT COOL. 

 

Summary of Contents for YUM K3000

Page 1: ...w information and models are released Visit our website for the latest manual Part Number FRY_IOM_8196647 11 2021 8196647 Original Instructions CAUTION READ THE INSTRUCTIONS BEFORE USING THE FRYER Kee...

Page 2: ...product button to cancel alarm Press and hold product button to cancel cook cycle Responding to Polish Prompt Controller displays Polish Now alternating with Yes No Press Yes button under Yes display...

Page 3: ...st dispose Total heads last dispose Number Press This is the number of heads cooked since the last dispose Last dispose date Press This is the date of the last dispose TEMP 300F TODAY Number Hrs Press...

Page 4: ...ss This is the total number of cooks since the last usage reset QUIT COOKS Number Press This is the total amount of cooks that were cancelled since the last reset usage On HOURS Number Press This is t...

Page 5: ...Controller displayed press System volume 9 Sets sound level for Controller Enter level 1 9 0 Lowest 9 Loudest Press Tempr format F Press to scroll choices F for Fahrenheit C for Celsius Press Exit Me...

Page 6: ...press the Exit Scan button three times to return the controller to OFF filter Blank Press Global filter count 20 Press Changes the total number of cooks that occur before a filter prompt The default...

Page 7: ...ange code use 10 for 0 Press Vat setup Current code 3228 Use numbered buttons to change code use 10 for 0 Press Exit Exit Press button once and press to scroll to System Time Date Filter E Log Change...

Page 8: ...ue when complete OPEN RETURN VALVE Open return valve Polishing 5 minute countdown timer None required Fill vat YES Press YES CLOSE DRAIN VALVE CONFIRM Close drain valve and press CONFIRM filling None...

Page 9: ...ion Action Polish Now Yes NO Respond to prompt with button push Press YES or NO Yes produces a filter detailed below No delays filter and cooking continues Add FILTER POWDER CONFIRM Add filter powder...

Page 10: ...d name of the product COOKING MODE SINGLE SETPOINT Segmented If multiple setpoint or segmented cooking is desired press MULTIPLE SETPOINT and go to 1 9 and follow the instructions Non Segmented Leave...

Page 11: ...ort none The duration of the audible alarm is optional Navigate choice with arrow buttons under display 2 Alarm Time Time The second point in the cook cycle an alarm sounds 2 Alarm Name Shake stir num...

Page 12: ...previously entered time Enter 0 00 Press 1 Alarm TIME 0 00 or previously entered time Subtract the time from the starting cook time when the alarm should sound Example If a cook time is 5 00 and the...

Page 13: ...first cooking segment 2 minutes and the setpoint of the first temperature change Step 3 sets the duration of the second cooking segment 4 minutes and the setpoint of the second temperature change Ste...

Page 14: ...s are entered at the point in the countdown they are desired The example below is for alarms at 11 00 6 00 and 2 00 on the countdown clock the alarms will occur two seven and 11 minutes into the 13 mi...

Page 15: ...rs 2 Time 0 00 or previously entered time Enter time remaining after first temperature change see page 1 11 and press 2 Tempr 0 00 or previously entered temperature Enter first temperature change and...

Page 16: ...s the alarm time Enter that time for shaking stirring etc Press 2 Alarm name name Press to scroll through choices and press 2 alarm mode Manual or auto Choose mode with and press 2 Alarm Tone Short me...

Page 17: ...omputer OFF press and hold check button Oil Stats Enter 1724 Vat Setup System 1 4 Language 2nd Language Locale CE or Non CE Energy Type Vat System Volume Level Tempr Format F or C Exit Melt Tempr Setb...

Page 18: ...a small component may often be indicative of potential failure or incorrect functioning of a more important component or system If you are in doubt as to the proper action to take do not hesitate to...

Page 19: ...all your FAS for assistance Controller displays Hi temp Frypot temperature is more than 40 F 4 C Press the power button to turn off fryer and let cool before returning power to fryer If issue continue...

Page 20: ...rain valve switch plugged vacuum pressure switch failed blower motor Check drain valve high limit vacuum pressure switch blower motor If it continues shut the fryer down and call your FAS for assistan...

Page 21: ...reading is out of range E05 HOT HI 1 High limit temperature is past more than 410 F 210 C or in CE countries 395 F 202 C E06 HEATING FAILURE A component has failed such as controller interface board c...

Page 22: ...3 318 865 1711 WWW FRYMASTER COM EMAIL FRYSERVICE WELBILT COM 2021 Welbilt Inc except where explicitly stated otherwise All rights reserved Continuing product improvement may necessitate change of spe...

Reviews: