![Frymaster YUM K3000 Operation Manual Download Page 21](http://html1.mh-extra.com/html/frymaster/yum-k3000/yum-k3000_operation-manual_2340329021.webp)
2-4
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Controller displays
OIL IN DRAIN
PAN / CONFIRM
Drain valve open or possibility that
oil is in drain pan.
Press
(CONFIRM) and follow directions for
FILL VAT FROM DRAIN PAN.
Controller displays
FLT DYLD
A filter cycle has been delayed.
This is a normal display when a filter has been
delayed. After the next filter prompt press
YES to filter.
Controller displays
POL DYLD
A polish cycle has been delayed.
This is a normal display when a polish has
been delayed. After the next polish prompt
press YES.
2.2.3 Error Log Codes
Code
ERROR MESSAGE
EXPLANATION
E03
ERROR TEMP PROBE FAILURE
Temp probe reading out of range
E04
HI 2 BAD
High limit reading is out of range.
E05
HOT HI 1
High limit temperature is past more than 410
°
F
(210
°
C), or in CE countries, 395
°
F (202
°
C)
E06
HEATING FAILURE
A component has failed such as controller, interface
board, contactor, gas valve, ignition module or
open-high limit.
E20
INVALID CODE LOCATION
SD card removed during update
E21
FILTER PAPER PROCEDURE ERROR
(Change Filter Paper)
24 hour timer has expired
E22
OIL IN PAN ERROR
Oil may be present in the filter pan.
E25
RECOVERY FAULT
Recovery time exceeded maximum time limit.
E28
HIGH TEMP ALARM
Oil has exceeded 40 ºF (4ºC) over setpoint.
2.2.4 HP Pressure Fryer Specific
The HP pressure fryer has a STRATIFY mode that turns the pump on for various times to mix the
oil so that excess water can escape from the oil.
It enters STRATIFY mode when:
-The fryer reaches 300F (149C) after initially heating.
-Every 30 minutes after cooks.
-After an EXIT COOL.