![Frymaster YUM K3000 Operation Manual Download Page 12](http://html1.mh-extra.com/html/frymaster/yum-k3000/yum-k3000_operation-manual_2340329012.webp)
1-11
1.8 Programming for Single Setpoint (Non-Segmented) Items
Programming for non-segmented food items is shown below. The right column has the action necessary to continue. Exit
from a programming step at any time by pressing the Scan button until the display returns to its pre-programming status.
Left Display
Right Display
Action
OFF
OFF
Press and hold
until Product Setup is displayed.
Product Setup
Blank
Press
.
Product Setup
Enter Code
Enter 1724.
Select Product
Blank
Press desired product button 1-20 that is not currently used to program
new product otherwise press a product button that is not lit.
Long Name
Product name or button
number
Enter product name with letter buttons. Advance cursor with
.
Press
.
Short Name
Abbreviated Product name or
button number
Enter abbreviated four character product name with letter buttons.
Press
.
COOKING MODE
SINGLE SETPOINT
Press
. If multiple setpoint or segmented cooking is desired press
MULTIPLE SETPOINT and go to 1.9 and follow the instructions.
(Default is SINGLE SETPOINT)
1 Time
0:00 or previously entered time
Enter total cook time with numbered buttons. Press
.
1 TempR
Temp
Enter cooking temperature. Press
.
1 Flex
Number
Enter the level of flex, 0-9, for the product. Press
.
1 PRESSURE
SOLENOID
OPEN
Set to desired position with the
buttons. Press the
button to
change to CLOSED.
(Option only for pressure fryers.)
2 Time
0:00 or previously entered time
Enter 0:00. Press
.
1 Alarm TIME
0:00 or previously entered time
Subtract the time from the starting cook time when the alarm should
sound. (Example: If a cook time is 5:00 and the shake time should be
30 seconds into the cook time enter 4:30 as the alarm time). Enter that
time for shaking, stirring, etc. Press
. (Note: If alarm time is set to
0:00 skip to After Cooking below.)
1 alarm name
shake
Press
to scroll through the alarm names (ex. Shake). Press
.
1 ALARM MODE
AUTO OR MANUAL
Press
to scroll to Auto or Manual alarm mode. Press
.
1 alarm tone
Short, medium, long double or
long short, none
Press
to scroll to choice of alarm tones. Press
.
2 alarm time
0:00
Press
. Leave at 0:00 for non-segmented cooking.
After Cooking
Cool or Setpt
Press
to scroll to Cool or Setpoint mode the fryer should exit to
after cook cycle: cool = 250; Setpoint = cooking temp. Press
.
Filter Lockout
0
Enter number of cook cycles before a filter prompt and press
.
QUANTITY?
No
Press
to scroll to YES if a quantity per load is required, otherwise
leave to default NO.
Head Count
0 or previously set number
Enter number of head or the equivalent value for the product. Press
.
Instant On
0
This is the time, in seconds, the fryer heats before the Controller
checks the temperature. Enter value and press
.
Exit
Exit
Press Scan button to exit or the
button for additional programming.
Select Product
Blank
More Programming? Press product button and follow instructions
above. Exit Programming? Press Scan Button.
Product Setup
Blank
Press Scan button to exit or the
button for additional programming.
OFF
OFF