![Frymaster YUM K3000 Operation Manual Download Page 11](http://html1.mh-extra.com/html/frymaster/yum-k3000/yum-k3000_operation-manual_2340329011.webp)
1-10
1.7 Prompts Encountered While Programming cont.
Left Display
Right Display
Explanation/Action
3 PRESSURE
SOLENOID
OPEN
See 1 Pressure Solenoid.
4 Time
Time
Segmented:
Enter time remaining in the cook cycle after the third
temperature change occurs.
Non-Segmented:
Doesn’t appear.
4 Tempr
Temperature
Segmented:
This is the third temperature change, which occurs at the point
entered at the 3 Time prompt.
Non-Segmented:
Doesn’t appear
4 Flex
On or Off
See 1 Flex.
4 PRESSURE
SOLENOID
OPEN
See 1 Pressure Solenoid.
5 Time
Time
Segmented:
Enter 0:00 if no more segments are needed.
Non-Segmented:
Doesn’t appear.
1 Alarm Time
Time
An audible alarm in the cook cycle, indicating a need to shake or stir the
product.
1 Alarm Name
Shake, stir, numbered alarm
Navigate choice with arrow buttons under display.
1 Alarm Mode
Manual or Auto
The alarm can be self cancelling (Auto) or manually canceled (Manual),
which requires a button push. Navigate choice with arrow buttons under
display.
1 Alarm Tone
Short, Medium, Long, double
or long short, none
The duration of the audible alarm is optional. Navigate choice with arrow
buttons under display.
2 Alarm Time
Time
The second point in the cook cycle an alarm sounds.
2 Alarm Name
Shake, stir, numbered alarm
Navigate choice with arrow buttons under display.
2 Alarm Mode
Manual or Auto
Navigate choice with arrow buttons under display.
2 Alarm Tone
Short, Medium, Long, double
or long short, none
Navigate choice with arrow buttons under display.
3 Alarm Time
Time
The third point in the cook cycle an alarm sounds.
3 Alarm Name
Shake, stir, numbered alarm
Navigate choice with arrow buttons under display.
3 Alarm Mode
Manual or Auto
Navigate choice with arrow buttons under display.
3 Alarm Tone
Short, Medium, Long, double
or long short, none
Navigate choice with arrow buttons under display.
After Cooking
Set Point or COOL
Setpoint
: Fryer remains at setpoint;
Cool:
Fryer holds at 250°F (121°C).
Filter Lockout
Number
Number of cook cycles for the product before a filter prompt.
Head Count
0
Number of heads of chicken or the equivalent number for a non-chicken
product.
Instant On
0
This is the time, in seconds, the fryer heats before the Controller checks the
temperature.
Exit
Exit
Press