Frymaster YUM K3000 Operation Manual Download Page 20

 

2-3 

 

PROBLEM 

PROBABLE CAUSES 

CORRECTIVE ACTION 

Controller displays 

HEATING 

FAILURE

Contactor issue, gas valve off, 
failed Controller, failed 
transformer, open high-limit 
thermostat. 

It is normal for this message to appear during 
startup if a gas fryer’s lines have air in them.  
Check that the gas valve is on. If it continues, 
shut the fryer down and call your FAS for 
assistance. 

Controller displays  

SERVICE 

REQUIRED

 followed 

by an error message. 

An error has occurred which 
requires a service technician.  

Press 

 (NO) to continue cooking and call 

your FAS for assistance. In some cases, 
cooking may not be allowed. 

Controller heat LED 

illuminated but fryer is 

not heating. (HP 

Pressure fryers only) 

Main power switch is off. 

Turn on main power switch and ensure 
heating lamp is illuminated. 

Controller displays 

HEATING 

FAILURE, CHECK 

HI-LIMIT, DRAIN 

VALVE, VACUUM 

SWITCH, BLOWER 

MOTOR.

 

(HP Pressure 

fryers only)

Open high-limit, open drain valve, 
faulty drain valve switch, plugged 
vacuum pressure switch, failed 
blower motor. 

Check drain valve, high-limit, vacuum 
pressure switch, blower motor.   
If it continues, shut the fryer down and call 
your FAS for assistance. 

 

  
2.2.2 Filtration 

Problems

 

 

PROBLEM 

PROBABLE CAUSES 

CORRECTIVE ACTION 

Controller 

displays 

IS VAT 

FULL? YES 

NO

 after a  

filtration. 

A. Normal after filtering or filling. 
 

A.   Press 

 (YES) if the vat is full, otherwise 

press 

 (NO) and follow prompts. 

CLEAN, POLISH, 

FILTER OR 

DISPOSE

 won’t 

start. 

Temperature too low or Controller 
displays OFF. 

Ensure fryer is at 250°F(121°C) or setpoint  
before starting; ensure the Controller is ON.

 

Controller displays 

WAIT FOR  

Filter

A.  Another function is still in 

process.  

B.  MIB has not cleared checking 

system. 

A.  Wait until the previous function ends to 

start another filtration cycle. 

B.  Wait one minute and try again. 

Controller displays 

CHANGE FILTER 

PAPER? 

Daily filter paper change prompt 
has occurred. 

Press 

 (YES), follow prompts and change 

the filter paper.  Do 

NOT

 ignore 

CHANGE 

FILTER PAPER

 prompts. 

Controller displays 

INSERT pan

A. Normal during Change Filter 

Paper routine. 

A. Insert pan and press 

 (CONFIRM) 

button. 

Summary of Contents for YUM K3000

Page 1: ...w information and models are released Visit our website for the latest manual Part Number FRY_IOM_8196647 11 2021 8196647 Original Instructions CAUTION READ THE INSTRUCTIONS BEFORE USING THE FRYER Kee...

Page 2: ...product button to cancel alarm Press and hold product button to cancel cook cycle Responding to Polish Prompt Controller displays Polish Now alternating with Yes No Press Yes button under Yes display...

Page 3: ...st dispose Total heads last dispose Number Press This is the number of heads cooked since the last dispose Last dispose date Press This is the date of the last dispose TEMP 300F TODAY Number Hrs Press...

Page 4: ...ss This is the total number of cooks since the last usage reset QUIT COOKS Number Press This is the total amount of cooks that were cancelled since the last reset usage On HOURS Number Press This is t...

Page 5: ...Controller displayed press System volume 9 Sets sound level for Controller Enter level 1 9 0 Lowest 9 Loudest Press Tempr format F Press to scroll choices F for Fahrenheit C for Celsius Press Exit Me...

Page 6: ...press the Exit Scan button three times to return the controller to OFF filter Blank Press Global filter count 20 Press Changes the total number of cooks that occur before a filter prompt The default...

Page 7: ...ange code use 10 for 0 Press Vat setup Current code 3228 Use numbered buttons to change code use 10 for 0 Press Exit Exit Press button once and press to scroll to System Time Date Filter E Log Change...

Page 8: ...ue when complete OPEN RETURN VALVE Open return valve Polishing 5 minute countdown timer None required Fill vat YES Press YES CLOSE DRAIN VALVE CONFIRM Close drain valve and press CONFIRM filling None...

Page 9: ...ion Action Polish Now Yes NO Respond to prompt with button push Press YES or NO Yes produces a filter detailed below No delays filter and cooking continues Add FILTER POWDER CONFIRM Add filter powder...

Page 10: ...d name of the product COOKING MODE SINGLE SETPOINT Segmented If multiple setpoint or segmented cooking is desired press MULTIPLE SETPOINT and go to 1 9 and follow the instructions Non Segmented Leave...

Page 11: ...ort none The duration of the audible alarm is optional Navigate choice with arrow buttons under display 2 Alarm Time Time The second point in the cook cycle an alarm sounds 2 Alarm Name Shake stir num...

Page 12: ...previously entered time Enter 0 00 Press 1 Alarm TIME 0 00 or previously entered time Subtract the time from the starting cook time when the alarm should sound Example If a cook time is 5 00 and the...

Page 13: ...first cooking segment 2 minutes and the setpoint of the first temperature change Step 3 sets the duration of the second cooking segment 4 minutes and the setpoint of the second temperature change Ste...

Page 14: ...s are entered at the point in the countdown they are desired The example below is for alarms at 11 00 6 00 and 2 00 on the countdown clock the alarms will occur two seven and 11 minutes into the 13 mi...

Page 15: ...rs 2 Time 0 00 or previously entered time Enter time remaining after first temperature change see page 1 11 and press 2 Tempr 0 00 or previously entered temperature Enter first temperature change and...

Page 16: ...s the alarm time Enter that time for shaking stirring etc Press 2 Alarm name name Press to scroll through choices and press 2 alarm mode Manual or auto Choose mode with and press 2 Alarm Tone Short me...

Page 17: ...omputer OFF press and hold check button Oil Stats Enter 1724 Vat Setup System 1 4 Language 2nd Language Locale CE or Non CE Energy Type Vat System Volume Level Tempr Format F or C Exit Melt Tempr Setb...

Page 18: ...a small component may often be indicative of potential failure or incorrect functioning of a more important component or system If you are in doubt as to the proper action to take do not hesitate to...

Page 19: ...all your FAS for assistance Controller displays Hi temp Frypot temperature is more than 40 F 4 C Press the power button to turn off fryer and let cool before returning power to fryer If issue continue...

Page 20: ...rain valve switch plugged vacuum pressure switch failed blower motor Check drain valve high limit vacuum pressure switch blower motor If it continues shut the fryer down and call your FAS for assistan...

Page 21: ...reading is out of range E05 HOT HI 1 High limit temperature is past more than 410 F 210 C or in CE countries 395 F 202 C E06 HEATING FAILURE A component has failed such as controller interface board c...

Page 22: ...3 318 865 1711 WWW FRYMASTER COM EMAIL FRYSERVICE WELBILT COM 2021 Welbilt Inc except where explicitly stated otherwise All rights reserved Continuing product improvement may necessitate change of spe...

Reviews: