LOV
™
Generation II Technical Reference
25
M3000 Useful Codes
To enter any of the following codes: Press and hold
and
simultaneously for
TEN
seconds; three
chirps sounds. The computer displays
TECH MODE
TECH MODE
. Enter the codes below to perform this function.
•
0042
0042
–
Reset
RECOVERY FAULT CALL SERVICE
RECOVERY FAULT CALL SERVICE
.
•
1658
1658
–
Change from F° to C°.
The computer displays
off
off
. Turn the computer on and check
temperature to see the temperature scale. If the desired scale is not displayed, repeat.
•
3322
3322
–
Reset Factory Menu.
The computer displays
COMPLETE
COMPLETE
, and then
off
off
. (
NOTE
:
This will delete any hand-entered menu items.)
•
1650
1650
–
Enter Tech Mode.
See page 1-36 to reset passwords and change fi lter pad time.
•
1212
1212
–
Switch Between Domestic and International Menu.
The computer displays
COMPLETE
COMPLETE
, and then
off
off
. (
NOTE
: This will delete any hand-entered menu items.)
•
0469
0469
–
Reset
Filter Stat Data
Filter Stat Data
.
The following codes require the removal and reinsertion of the J3 locator plug on the rear of the computer
before entering the code.
•
1000
1000
–
Reset
CALL TECH
CALL TECH
Message.
Disconnect board locator plug (J10). Reinsert plug.
Enter
1000
1000
. Computer display switches to
off
off
. Remove and then restore power to the computer
using the 20-pin plug.
•
9988
9988
–
Reset
BADCRC
BADCRC
Message.
Disconnect board locator plug (J10). Reinsert plug. Enter
9988
9988
. Computer display switches to
off
off
. Remove and then restore power to the computer using
the 20-pin plug. Replace the computer.
The following codes are entered when prompted to do so or from an energy misconfi gured exception error.
•
1111
1111
–
Reset
SERVICE REQUIRED
SERVICE REQUIRED
Message.
Enter this when the issue is fi xed and you
are prompted to enter.
•
1234
1234
–
Enter
SETUP MODE
SETUP MODE
from energy misconfi gured exception error.
(This usu-
ally can be done without pressing the fi lter buttons if an error is displayed.)
Passwords
To enter level one, level two passwords –
Press and hold the
TEMP
and
INFO
buttons simultane-
ously until
level 1
level 1
or
level 2
level 2
is displayed. Release the buttons and
ENTER
ENTER
Code
Code
appears.
•
1234
1234
–
Fryer Setup, Level One, and Level Two.
•
4321
4321
– Usage Password.