The HLZ has been
powered up and has
been running for at
least 20 minutes.
The computer
display reads:
PROB
One of the RTD
probes has
failed.
Press the plate heater
temp switch once to
see actual temp.
Is the plate
heater temp /-
15°F of programmed
temp?
Heater plate
RTD is good.
Press air heater
temp switch once
to see actual temp.
Is the air
heater temp /-
25°F of programmed
temp?
Computer may
be faulty.
Air heater RTD
probe is faulty.
Heater plate
RTD is faulty.
Contact your
authorized
Frymaster servicer.
HI
Press the plate heater
temp switch once to
see actual temp.
Is the plate
heater temp /-
15°F of programmed
temp?
Plate heater, plate
heater relay, or RTD
are faulty.
LO
Press the air heater
temp switch once to
see actual temp.
Is the air
heater temp /-
25°F of programmed
temp?
Air heater, air
heater relay, or
RTD are faulty.
Contact your
authorized
Frymaster servicer.
REdY
Unit has
reached
setpoint.
Do you feel hot
air coming out of the cowl
assembly?
Air heater is
good.
Press the heater plate
temp switch once to
read actual temp.
Press the heater plate
temp switch a second
time to read setpoint.
Is the actual
temp /- 15°F of
setpoint?
Heater plate is
good.
Your HLZ is
ready for use.
Yes
No
Yes
No
No
Yes
No
Yes
No
Yes
No
Yes