6.2.5 Auto Top Off Problems
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Frypots top off cold. Incorrect setpoint.
Ensure setpoint is correct.
One vat doesn’t top
off.
A.
Filter error exists.
B.
Service required error exists
C.
Solenoid, pump, pin issue, RTD or
ATO issue.
A.
Clear filter error properly. If
problem persists, call your FAS
for assistance.
B.
Call your FAS for assistance.
C.
Call your FAS for assistance.
Frypots won’t top
off.
A.
Fryer temperature too low.
B.
Oil is too cold.
C.
Top oil empty displayed
D.
Service required error exists
E.
Melting unit switch is off (only on
solid shortening units)
F.
Blown fuse.
A.
Fryer temperature must be at
setpoint.
B.
Ensure that the oil in the top off
reservoir is above 70°F (21°C).
C.
Ensure the top off reservoir is
not out of oil. Replace top off
reservoir or fill from bulk and
reset top off system.
If problem persists, call your FAS
for assistance.
D.
Call your FAS for assistance.
E.
Ensure the switch on the melting
unit is in the ON position.
F.
Check the fuse on the left of the
ATO box. If using a solid
shortening melting unit, check
the fuse below the melting unit
switch.
6.2.6 Bulk Oil System Problems
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Frypot won’t fill.
A.
Incorrect setup procedure.
B.
Dispose valve not completely
closed.
C.
Bulk oil tank is empty.
D.
RTI pump issue.
A.
Power cycle fryer by disconnecting and
reconnecting the bulk oil control
connector on rear of fryer.
B.
Ensure the dispose valve handle is
pushed fully closed.
C. Call your bulk oil provider.
D. Call you FAS for assistance.