2-3
2.2
Power Requirements
The optional three phase supply plug for 208v and 240v delta configuration fryers are rated at 60 amps,
250 VAC and is NEMA configuration 15-60P.
Three (3) Phase Requirements
MODEL
VOLTAGE
WIRE
SERVICE
MINIMUM WIRE
SIZE
AWG (mm)
AMPS
(per leg)
FQE60U 14kW
208
3
6
(4.11)
39
FQE60U 14kW
240
3
6
(4.11)
34
FQE60U 14kW
480
3
8
(2.59)
17
FQE60U 14kW
220/380
4
6
(4.11)
21
FQE60U 14kW
240/415
4
6
(4.11)
20
FQE60U 14kW
230/400
4
6
(4.11)
21
FQE60U 17kW
208
3
6
(4.11)
48
FQE60U 17kW
240
3
6
(4.11)
41
FQE60U 17kW
480
3
6
(4.11)
21
FQE60U 17kW
220/380
4
6
(4.11)
26
FQE60U 17kW
240/415
4
6
(4.11)
24
FQE60U 17kW
230/400
4
6
(4.11)
25
FQE60U 22kW
208
3
4
(5.19)
61
FQE60U 22kW
240
3
4
(5.19)
53
FQE60U 22kW
480
3
6
(4.11)
27
FQE60U 22kW
220/380
4
6
(4.11)
34
FQE60U 22kW
240/415
4
6
(4.11)
31
FQE60U 22kW
230/400
4
6
(4.11)
32
Single Phase Requirements
MODEL
VOLTAGE
WIRE
SERVICE
MINIMUM WIRE
SIZE
AWG (mm)
AMPS
(per leg)
FQE60U 14kW
208
2
3
(5.83)
68
FQE60U 14kW
240
2
4
(5.19)
59
FQE60U 14kW
480
2
8
(3.26)
30
NOTICE
If this appliance is permanently connected to fixed wiring, it must be connected by means of
copper wires having a temperature rating of not less than 167°F (75°C).
DANGER
This appliance must be connected to a power supply having the same voltage and phase as
specified on the rating plate located on the inside of the appliance door.
DANGER
All wiring connections for this appliance must be made in accordance with the wiring diagram(s)
furnished with the appliance. Refer to the wiring diagram(s) affixed to the inside of the
appliance door when installing or servicing this equipment.