Frymaster FilterQuick Version 2 Operation Manual Download Page 9

1-4 

 

1.3   Setup: Main Menu

 

  

Pressing and holding the checkmark key for 10 seconds produces the setup mode, which first displays Product Setup. Turn 
the controller off and follow the steps below to navigate the options. 

 

Left Display

 

Right Display

 

Action

 

OFF OFF 

Start with the far left controller.

  

Press and hold the 

 (check) button until the controller 

scrolls 

INFO MODE

, changing to 

MAIN MENU

 and then 

PRODUCT SETUP

.  

Product Setup   

Press 

 to scroll to Product Setup, Vat Setup, Tech Mode, and Exit. With the desired 

selection displayed, press 

Product Setup   

Used to program menu items and cooking parameters.    

vat setup 

 

Vat set up is described below in section 1.4. 

Tech Mode 

 

Tech mode is used to enable and disable Cooks and Filters options. 

Exit 

Exit 

Press Exit/Scan button to return the controller to OFF. 

 

1.4  Vat Setup 

 

 

Vat Setup mode allows the controller to be set for language displays, vat sizes, and temperature range displays. With the 
controller OFF, follow the steps below. *

NOTE: Most of the system choices are only available on the far left (Master) 

controller. Vat type, Cool Mode Default and Basketlift are only available on other controllers. 

 

  

Left Display 

 

Right Display

 

Action 

 

OFF OFF 

Start with the far LEFT controller.  Press and hold the 

 (check) button until the 

controller scrolls Info Mode, changing to MAIN MENU and then PRODUCT 
SETUP.  

PRODUCT 
SETUP  

Press 

 to scroll to Vat setup and press 

.   

VAT SETUP 

Enter 
code 

Enter 1656. 

SYSTEM 

Press 

Language English 

Press 



 to scroll to choice and press 

.   

2nd 
language 

SPANISH 

Press 



 to scroll to choice and press 

.  

(This option allows another language to 

be toggled from the front panel. (ex. Spanish as a second language.) Default is 
Spanish.

 

Locale Non-CE 

Press 



 to scroll to choices: CE (European Conformity standards),  or Non-CE 

(non-European standards) and press 

.  This option is available only on the far left 

controller. 

Energy Gas 

Press 



 to scroll to choices: Gas or Electric and press 

This option is available 

only on the far left controller.

 

Type GL30 

Full 

Press 



 to scroll choices: 

Gas-

 GL30 Full, GL30 Split, GL30 Full OSP, GL30 

Split OSP, 11814 Full   

Electric-

 EL30-14 Full, EL30-14 Split, EL30-17 Full, EL30-

17 Split, 11817 Full. With the current fryer vat type displayed, press 

SYSTEM 
volume 

Sets sound level for controller. Enter level, 1-9 (1=Lowest/ 9=Loudest).  Press 

Tempr 
format 

Press 



 to scroll choices: F for Fahrenheit;   C for Celsius. Press 

Exit Melt 
Tempr 

180º  
(82 ºC) 

Use numbered keys to change default setting. Press 

. (This is the temperature for 

the fryer to exit the melt cycle.) Range is 100°F (38°C) to 200°F (93°C).  Default is 
180°F (82°C). 

COOL MODE 
TEMPR 

250F (121 
ºC) 

Use numbered keys to change default setting. Press 

. (This is the temperature 

during setback or idle mode.) Default is 250°F (121°C).  

COOL MODE 
DEFAULT 

0  

Use numbered keys to change default setting. (This is the amount of minutes the 
fryers sits idle before going to cool mode. The default, 0, disables the feature.) Press 

.   

FRESH OIL  JIB 

Press 



 to scroll choices JIB or Bulk.  Default is JIB.  Press 

 

WASTE SDU 

Press 



 to scroll choices SDU, BULK or FRONT.  Default is SDU. Press 

 

Summary of Contents for FilterQuick Version 2

Page 1: ...on 2 For push button FilterQuick fryers Operation Manual This manual is updated as new information and models are released Visit our website for the latest manual Part Number FRY_IOM_8197206 01 2018 8...

Page 2: ...ED WITH CONTROLLERS U S This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must...

Page 3: ...iters or more for FQE30 or FQG30 fryers or EIGHT gallons 30 liters or more for 1814E or 1814G fryers Otherwise boil out solution could overflow and can cause injury DANGER Open the filter pan slowly t...

Page 4: ...e disposal area WARNING Never leave the fryer unattended during the boil out process If the solution overflows press the ON OFF switch to the OFF position immediately WARNING This appliance is not int...

Page 5: ...Pan to Waste Bulk only 1 18 1 9 10 Clean Hot Boil Out or Cold Cold Soak Dispose SDU or Alternate Container Manually Fill Vat from JIB 1 19 1 9 11 Clean Hot Boil Out or Cold Cold Soak Dispose to Bulk o...

Page 6: ...on Navigation Product Press to start a cook cycle Active when adjacent LED is lit LED flashes during a cook cycle Press and hold to cancel a cook cycle Press at end of cook cycle to cancel an alarm Pr...

Page 7: ...1 2 1 2 Menu Trees 1 2 1 FilterQuick Controller Menu Setup Tree...

Page 8: ...1 3 1 2 2 FilterQuick Filter and Info Mode Menu Tree...

Page 9: ...SYSTEM Press Language English Press to scroll to choice and press 2nd language SPANISH Press to scroll to choice and press This option allows another language to be toggled from the front panel ex Spa...

Page 10: ...2 00 A M on the second Sunday in March Clocks move ahead one hour Daylight saving time ends at 2 00 A M on the first Sunday in November Clocks move back one hour For the two U S states and internation...

Page 11: ...30 minutes Press POLISH LOCKOUT DISABLED Press to scroll to choice enable or disable and press Default is DISABLED If enabled allows a polish to be bypassed once On the next polish prompt the vat mus...

Page 12: ...ress the Exit Scan button once to return the controller to OFF E LOG OFF OFF Press until the controller scrolls INFO MODE changing to MAIN and then PRODUCT SETUP PRODUCT SETUP Press to scroll to Vat S...

Page 13: ...hes since dispose Number Press This is the number of polishes since oil disposal Polishes by passed SINCE DISPOSE Number Press This is the number of by passed polishes since oil disposal Oil Life Numb...

Page 14: ...s This is the total number of hours the fryer was on since start of the selected period Reset usage Yes no Press to scroll or to set start of new selected period stats Reset usage Enter code Enter 165...

Page 15: ...l cook time with numbered keys Press 1 TEMPR 350F or previously entered temperature Enter cooking temperature Press 1 Sensitivity Number Enter the level of sensitivity 0 9 for the product Press 1 alar...

Page 16: ...similar table of time temperature changes before beginning the programming process Step 1 sets total cook time and initial setpoint Step 2 sets the duration of the first cooking segment 2 minutes and...

Page 17: ...ime 0 00 or previously entered time Leave at zero if no more segments are needed and press If more segments are needed continue programming as shown above Five is the limit 5 TEMPR 0 or previously ent...

Page 18: ...a Clean and Filter or a Polish All messages need to be confirmed or cleared on all controllers prior to starting any filtration process NOTE Some functions are only available when the controller is on...

Page 19: ...D is displayed will prompt a filter If the controller is turned OFF during the clean now prompt or when FLT DLYD is displayed it will return once the controller is soft powered on again If filter lock...

Page 20: ...ISPOSE Press button with blinking LED DISPOSING None required If the drain becomes clogged use the Fryer s Friend to clear the blockage VAT EMPTY AND CLEAN CONFIRM Press arrow under CONFIRM Remove Dis...

Page 21: ...displays OFF START DISPOSE Press button with blinking LED DRAINING None required If the drain becomes clogged use the Fryer s Friend to clear the blockage VAT EMPTY and clean CONFIRM Press arrow unde...

Page 22: ...ns to FILLING for another 45 seconds If vat is not full after two attempts go to next line REMOVE FILTER PAN Open the door and pull filter pan out of the cabinet IS PAN EMPTY YES NO Ensure the pan is...

Page 23: ...nly Left Display Right Display Action Follow steps to Entering Filter Menu Mode on page 1 11 LEFT Split vats only RIGHT Split vats only Press appropriate arrow to select side PAN TO WASTE Press PAN TO...

Page 24: ...SING If the drain becomes clogged use the Fryer s Friend to clear the blockage VAT EMPTY AND CLEAN CONFIRM Press arrow under CONFIRM REMOVE DISPOSAL UNIT CONFIRM Remove disposal unit and press arrow u...

Page 25: ...ONFIRM when empty OPEN DISPOSE valve Pull the dispose handle Note If using front dispose ensure the wand is connected to the quick disconnect port Press and hold switch after pulling the dispose handl...

Page 26: ...return to OFF WASTE TANK FULL CONFIRM If waste tank is full this message is displayed Press button to CONFIRM and call waste oil provider Controller displays OFF IS OIL REMOVED YES NO Press YES arrow...

Page 27: ...to continue filling OFF OFF 1 10 Polishing The FilterQuick controller displays a series of prompts when a polish filter cycle is under way To initiate a polish press and hold the arrows simultaneously...

Page 28: ...Long name 8 character product name Press to progress to next product stat Short Name 4 character abbreviated product name Press to progress to next product stat COOKS REMAINING Number or DISABLED Num...

Page 29: ...ime in seconds the fryer heats before the controller checks the temperature NOTE An incorrect entry may cause the fryer to overshoot temperature and over cook some products Press HOLD time 0 00 or pre...

Page 30: ...ure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system If you are in doubt as to the proper action to take do not hesita...

Page 31: ...r FAS for assistance Controller displays Hi temp Frypot temperature is more than 40 F 4 C over setpoint Press the power button to turn off fryer and let cool before returning power to fryer If issue c...

Page 32: ...e oil level sensor may be coated with caramelized oil B CAN communication issues component failure issues C OIB relay ground issue A Clean sensor with scratch pad B If the issue persists contact your...

Page 33: ...llow prompts and change the filter paper Ensure the filter pan has been removed from the fryer for a minimum of 30 seconds Do NOT ignore CHANGE FILTER PAPER prompts Controller displays INSERT pan A No...

Page 34: ...ress to decline Press Exit Exit Press Exit Scan twice OFF OFF This test will ruin the oil and should only be conducted by a technician 2 2 4 Error Log Codes Code ERROR MESSAGE EXPLANATION E03 ERROR TE...

Page 35: ...lid OQS reading Filter at a temperature between 300 F 149 C and 375 F 191 C E71 OQS TEMP LOW Oil temperature is too low for a valid OQS reading Filter at a temperature between 300 F 149 C and 375 F 19...

Page 36: ...pect the pre screen filter and ensure it is screwed in tightly Inspect the O rings on the filter pan and ensure they are both present and that they are not missing cracked or worn If so replace them E...

Page 37: ...SOON CONFIRM OIL IS GOOD or DISCARD NOW is shown DISCARD NOW 24 Use numbered keys to change the default setting of the TPM DISCARD NOW value and press Default is 24 Minimum value is 15 maximum value...

Page 38: ...the following pages to navigate the modes If the filter pan is not fully engaged the controller displays INSERT PAN Once the filter pan is pushed fully into place and the MIB board displays an A the...

Page 39: ...QS Set to Text Left Display Right Display Action Follow steps to Entering Filter Menu Mode above in section 3 3 LEFT Split vats only RIGHT Split vats only Press appropriate arrow to select side CLEAN...

Page 40: ...nutes CLOSE DRAIN CONFIRM Press arrow under CONFIRM FILLING None required IS VAT FULL YES NO Press YES if the vat is full Press NO to continue filling OFF OFF 3 3 3 OQS Filter with OQS Set to Number L...

Page 41: ...ILLING None required TPM X X alternating None required The pump stops and the OQS sensor calculates the TPM value of the oil FILLING None required The pump continues filling the frypot IS VAT FULL YES...

Page 42: ..._IOM_8197206 01 2018 8197423 WWW WELBILT COM Welbilt provides the world s top chefs and premier chain operators or growing independents with industry leading equipment and solutions Our cutting edge d...