1-17
DANGER
DO NOT
attempt to drain more than one full frypot or two split frypots into the SDU
at one time.
3.
Position a container beneath the oil return fitting at the front of the cabinet. Disconnect the
flexible oil line from the fitting, allowing any residual oil to drain into the container.
4.
At the rear of the fryer, unplug the left connector (as viewed from the rear of the fryer) from the
transformer box. Using a pin pusher, push the pump solenoid valve wires from Pins 7 and 9.
5.
Remove the four nuts and bolts attaching the motor mount to the rear motor mount support.
6.
At the front of the fryer, remove the cover plate from the front of the motor and disconnect the
motor wires.
7.
Place a 1-foot (30.5-cm) length of wood (or similar support) beneath the motor mount near the
front of the unit and remove the two remaining nuts and bolts attaching the motor mount to the
front cabinet cross-brace.
8.
Carefully remove the support and lower the motor mount to the floor, allowing the rear of the
mount to slide forward and off the rear motor mount support.
9.
Disconnect the return flexline from the pump. The motor and pump assembly can now be pulled
from beneath the fryer and the failed component can be removed and replaced.
10.
Position the new/repaired motor and pump assembly beneath the fryer and reconnect the oil
return flexline to the pump. Lift the rear of the motor mount up and onto the rear motor mount
support.
11.
Lift the front of the motor mount up and support it with a 1-foot (30.5-cm) piece of wood or a
similar support. Install but do not tighten the two nuts and bolts that attach the motor mount to
the front cabinet cross-brace.
12.
Install and tighten the four nuts and bolts that secure the motor mount to the rear motor mount
support. Reconnect the solenoid valve wires to Pins 7 and 9 of the 9-pin connector (polarity
does not matter) and reconnect the plug.
13.
At the front of the fryer, tighten the two nuts and bolts at the front of the motor mount.
Reconnect the motor power wires and reinstall the wiring cover plate.
14.
Reconnect the oil return flexline and reinstall the filter pan.
15.
Reconnect the unit to the electrical power supply, fill the frypots with oil and check for proper
operation.
1.6.10 Replacing the Frypot
1.
Disconnect the fryer from the electrical and gas supplies.
Summary of Contents for BIPH52 Series
Page 28: ...1 21 Disassembling A Frypot Full Vat Illustrated Spacers Spacer 10 2 3 4 5 6 7 8 1 11 9 ...
Page 46: ...1 39 1 11 2 Transformer Filter Boxes 1 11 2 1 MPH152 155 Transformer Filter Box ...
Page 48: ...1 41 1 11 2 3 BIPH252 255 and 452 455 Transformer Filter Box International 8051340C ...
Page 50: ...1 43 1 11 2 5 BIPH352 355 Transformer Filter Box International ...
Page 66: ...2 13 2 4 2 Drain Valves and Associated Components ...
Page 68: ...2 15 2 4 3 Rear Flush Oil Return Line Components ...
Page 72: ...2 19 2 5 2 Transformer Boxes ...
Page 76: ...2 23 2 7 Frypots and Associated Components 2 7 1 Full Vat Frypot Components ...
Page 78: ...2 25 2 7 2 Dual Vat Frypot Components ...
Page 86: ...2 33 Transformer Box Cable Assemblies 1 2 3 4 5 6 7 8 9 10 11 ...