ELECTRICAL POWER SPECIFICATIONS
Three (3) Phase Requirements
kW VOLTAGE
PHASE
WIRE
SERVICE
MINIMUM SIZE
AMPS PER LEG
AWG mm2 L1 L2
L3
14 208
3
3
6
16
39
39
39
14 240
3
3
6
16
34
34
34
14 480
3
3
8
10
17
17
17
14 220/380
3 4 6
16
21
21
21
14 240/415
3 4 6
16
20
20
21
14 230/400
3 4 6
16
21
21
21
17 208
3
3
6
16
48
48
48
17 240
3
3
6
16
41
41
41
17 480
3
3
6
16
21
21
21
17 220/380
3 4 6
16
26
26
26
17 240/415
3 4 6
16
24
24
24
17 230/400
3 4 6
16
25
25
25
22 208
3
3
4
25
61
61
61
22 240
3
3
4
25
53
53
53
22 480
3
3
6
16
27
27
27
22 220/380
3 4 6
16
34
34
34
22 240/415
3 4 6
16
31
31
31
22 230/400
3 4 6
16
32
32
32
Single Phase Requirements
kW VOLTAGE
PHASE
WIRE
SERVICE
MINIMUM SIZE
AMPS
AWG mm2
14 208
1
2
3
34 68
14 240
1
2
4
25 59
14 480
1
2
8
10 30
Summary of Contents for 1814E Series
Page 22: ...1 17 1 13 Wiring Diagrams 1 13 1 Modular Basket Lift Wiring Diagram 208 250V...
Page 23: ...1 18 1 13 2 Modular Basket Lift Wiring Diagram 100 120V...
Page 24: ...1 19 1 13 3 Standard 1814E Control Wiring with 30000 Controls...
Page 25: ...1 20 1 13 4 BK1814E Control Wiring...
Page 26: ...1 21 1 13 5 Component Box Wiring...
Page 27: ...1 22 1 13 6 Tilt Switch Wiring...
Page 28: ...1 23 1 13 7 Contactor 17kW Full Vat DELTA Configuration Solid State Relay 208 250V...
Page 29: ...1 24 1 13 8 Contactor 17kW Full Vat DELTA Configuration Mechanical 208 250V...
Page 30: ...1 25 1 13 9 Contactor 17kW Full Vat DELTA Configuration Mechanical 480V...
Page 31: ...1 26 1 13 10 Contactor 17kW Dual Vat DELTA Configuration Solid State Relay 208 250V...
Page 32: ...1 27 1 13 11 Contactor 17kW Dual Vat DELTA Configuration Mechanical 208 250V 480V...
Page 33: ...1 28 1 13 12 Contactor 22kW Full Vat DELTA Configuration Solid State Relay 208 250V...
Page 34: ...1 29 1 13 13 Contactor 22kW Full Vat DELTA Configuration Mechanical 208 250V...
Page 35: ...1 30 1 13 14 Contactor 22kW Full Vat DELTA Configuration Mechanical 480V...
Page 38: ...1 33 1 13 17 Contactor 17kW Dual Vat WYE Configuration Export Solid State Relay 208 250V...
Page 39: ...1 34 1 13 18 Contactor 17kW Dual Vat WYE Configuration Export Mechanical 208 250V...
Page 41: ...2 2 2 2 Basket Lift Assembly and Associated Parts...
Page 48: ...2 9 2 4 2 Drain Valves and Associated Parts Units with Built In Filtration cont...
Page 51: ...2 12 2 5 Electronics and Wiring Components 2 5 1 Component Boxes...
Page 53: ...2 14 2 5 2 Contactor Boxes...
Page 57: ...2 18 2 5 3 2 Element Tube Assemblies...
Page 67: ...2 28 2 8 Oil Return System Components...