1-7
2.
Disconnect the fryer from the electrical power supply.
3.
Remove the two screws securing the cover of the contactor box. The contactor boxes above the
filter pan are accessed by sliding under the fryer. They are located to the left and right above the
guide rails (see photo below). The contactor boxes of non-filter units or frypots not over the
filter pan are accessed by opening the fryer door directly under the affected frypot.
4.
The contactors and relays are held on by threaded pin studs so that only removal of the nut is
required to replace the component.
5.
After performing necessary service, reverse steps 1-4 to return the fryer to operation.
Left and right views of mechanical contactor box components.
1.8 Replacing a Frypot
1.
Drain the frypot into the filter pan or, if replacing a frypot over the filter system, into a
Shortening Disposal Unit (SDU) or other appropriate metal container. If replacing a frypot over
the filter system, remove the filter pan and lid from the unit.
DANGER
DO NOT
drain more than one full frypot or two split frypots into the SDU at one time.
2.
Disconnect the fryer from the electrical power supply and reposition it to gain access to both the
front and rear.
3.
Remove the screws from the bottom of the bezel. Lower and remove the bezel.
Remove two screws to access contactor box components above the filter
pan
.
Summary of Contents for 1814E Series
Page 22: ...1 17 1 13 Wiring Diagrams 1 13 1 Modular Basket Lift Wiring Diagram 208 250V...
Page 23: ...1 18 1 13 2 Modular Basket Lift Wiring Diagram 100 120V...
Page 24: ...1 19 1 13 3 Standard 1814E Control Wiring with 30000 Controls...
Page 25: ...1 20 1 13 4 BK1814E Control Wiring...
Page 26: ...1 21 1 13 5 Component Box Wiring...
Page 27: ...1 22 1 13 6 Tilt Switch Wiring...
Page 28: ...1 23 1 13 7 Contactor 17kW Full Vat DELTA Configuration Solid State Relay 208 250V...
Page 29: ...1 24 1 13 8 Contactor 17kW Full Vat DELTA Configuration Mechanical 208 250V...
Page 30: ...1 25 1 13 9 Contactor 17kW Full Vat DELTA Configuration Mechanical 480V...
Page 31: ...1 26 1 13 10 Contactor 17kW Dual Vat DELTA Configuration Solid State Relay 208 250V...
Page 32: ...1 27 1 13 11 Contactor 17kW Dual Vat DELTA Configuration Mechanical 208 250V 480V...
Page 33: ...1 28 1 13 12 Contactor 22kW Full Vat DELTA Configuration Solid State Relay 208 250V...
Page 34: ...1 29 1 13 13 Contactor 22kW Full Vat DELTA Configuration Mechanical 208 250V...
Page 35: ...1 30 1 13 14 Contactor 22kW Full Vat DELTA Configuration Mechanical 480V...
Page 38: ...1 33 1 13 17 Contactor 17kW Dual Vat WYE Configuration Export Solid State Relay 208 250V...
Page 39: ...1 34 1 13 18 Contactor 17kW Dual Vat WYE Configuration Export Mechanical 208 250V...
Page 41: ...2 2 2 2 Basket Lift Assembly and Associated Parts...
Page 48: ...2 9 2 4 2 Drain Valves and Associated Parts Units with Built In Filtration cont...
Page 51: ...2 12 2 5 Electronics and Wiring Components 2 5 1 Component Boxes...
Page 53: ...2 14 2 5 2 Contactor Boxes...
Page 57: ...2 18 2 5 3 2 Element Tube Assemblies...
Page 67: ...2 28 2 8 Oil Return System Components...