1-3
1.4 Replacing a High-Limit Thermostat
1.
Remove the filter pan and lid from the unit. Drain the frypots into a Shortening Disposal Unit
(SDU) or other appropriate metal container.
DANGER
DO NOT
drain more than one full frypot or two split frypots into the SDU at one time.
2.
Disconnect the fryer from the electrical power supply and reposition it to gain access to the rear
of the fryer.
3.
Remove the four screws from both the left and right sides of the lower back panel.
4.
Locate the high-limit that is being replaced and follow the two-black wires to the 12-pin
connector C-6. Note where the leads are connected prior to removing them from the connector.
Unplug the 12-pin connector C-6 and using a pin-pusher push the pins of the high-limit out of
the connector.
5.
Using a wrench, carefully unscrew the high-limit thermostat to be replaced.
6.
Apply Loctite
™
PST 567 or equivalent sealant to the threads of the replacement and screw it
securely into the frypot.
7.
Insert the leads into the 12-pin connector C-6 (see illustration below). For full-vat units or the
left half of a dual-vat unit (as viewed from the rear of the fryer) the leads go into positions 1 and
2 of the connector. For the right half of a dual-vat unit (as viewed from the rear of the fryer), the
leads go into positions 7 and 8. In either case, polarity does not matter.
8.
Reconnect the 12-pin connecting plug C-6. Use wire ties to secure any loose wires.
9.
Reinstall the back panels reposition the fryer under the exhaust hood, and reconnect it to the
electrical power supply to return the fryer to service.
1.5 Replacing a Temperature Probe
1.
Remove the filter pan and lid from the unit. Drain the frypots into a Shortening Disposal Unit
(SDU) or other appropriate metal container.
DANGER
DO NOT
drain more than one full frypot or two split frypots into the SDU at one time.
Summary of Contents for 1814E Series
Page 22: ...1 17 1 13 Wiring Diagrams 1 13 1 Modular Basket Lift Wiring Diagram 208 250V...
Page 23: ...1 18 1 13 2 Modular Basket Lift Wiring Diagram 100 120V...
Page 24: ...1 19 1 13 3 Standard 1814E Control Wiring with 30000 Controls...
Page 25: ...1 20 1 13 4 BK1814E Control Wiring...
Page 26: ...1 21 1 13 5 Component Box Wiring...
Page 27: ...1 22 1 13 6 Tilt Switch Wiring...
Page 28: ...1 23 1 13 7 Contactor 17kW Full Vat DELTA Configuration Solid State Relay 208 250V...
Page 29: ...1 24 1 13 8 Contactor 17kW Full Vat DELTA Configuration Mechanical 208 250V...
Page 30: ...1 25 1 13 9 Contactor 17kW Full Vat DELTA Configuration Mechanical 480V...
Page 31: ...1 26 1 13 10 Contactor 17kW Dual Vat DELTA Configuration Solid State Relay 208 250V...
Page 32: ...1 27 1 13 11 Contactor 17kW Dual Vat DELTA Configuration Mechanical 208 250V 480V...
Page 33: ...1 28 1 13 12 Contactor 22kW Full Vat DELTA Configuration Solid State Relay 208 250V...
Page 34: ...1 29 1 13 13 Contactor 22kW Full Vat DELTA Configuration Mechanical 208 250V...
Page 35: ...1 30 1 13 14 Contactor 22kW Full Vat DELTA Configuration Mechanical 480V...
Page 38: ...1 33 1 13 17 Contactor 17kW Dual Vat WYE Configuration Export Solid State Relay 208 250V...
Page 39: ...1 34 1 13 18 Contactor 17kW Dual Vat WYE Configuration Export Mechanical 208 250V...
Page 41: ...2 2 2 2 Basket Lift Assembly and Associated Parts...
Page 48: ...2 9 2 4 2 Drain Valves and Associated Parts Units with Built In Filtration cont...
Page 51: ...2 12 2 5 Electronics and Wiring Components 2 5 1 Component Boxes...
Page 53: ...2 14 2 5 2 Contactor Boxes...
Page 57: ...2 18 2 5 3 2 Element Tube Assemblies...
Page 67: ...2 28 2 8 Oil Return System Components...