Frosty Keg KEG6000 Operating Manual Download Page 7

Be sure that you are thoroughly familiar with the assembly and installation process 
before turning on your kegerator.

IMPORTANT!

 You should position your unit in an upright position and allow to sit for 

at least 8-10 hours before plugging into an outlet. This will allow any refrigerant that 
has moved to settle back to where it should be before operation.

1

.

Your kegerator is shipped in double-walled cardboard for maximum protection 
(Figure 1). Remove this cardboard carefully. You may wish to leave the bottom 
cardboard panel beneath the kegerator to protect flooring when assembling 
guardrail, tower, tank and casters.

2. Your kegerator is also shipped with a protective plastic lining (Figure 2) on 

the door to protect it during assembly. To prevent scratches or accidental 
blemishes during the assembly process we recommend leaving this 
coating on until assembly is complete. 

3.

The unit is shipped ready for refrigerator use (Figure 3) with shelves in place. To 
use as a refrigerator simply remove the packaged parts and the keg board,  
insert the beer tower plug (see page 5 for parts list),  adjust the temperature 
settings, and after allowing ample time for the refrigerant to settle after shipping, 
plug in the unit. To assemble as a kegerator follow the rest of the assembly steps 
in this manual.

4.

Remove shelves, shelf rack and packaged parts from the kegerator cabinet. 
Unpack the parts and consult page 5 to become familiar with all assembly parts. 
Note: your unit ships with several extra washers; please be sure to keep these in 
a safe place with the manual in case you should ever need them.

1

.

To install the casters (page 5, F), first make sure everything is removed from the 

kegerator cabinet, then tilt the front side of the unit 
back slightly on a dry and padded surface. Do not tilt 
more than 30 degrees when installing casters to avoid 
jostling any refrigerant.

2.

Install casters into holes on bottom of kegerator as 

shown in Figure 4 and tighten with a 3/8” wrench (not 
provided). Two of the four casters provided are 
equipped with locks to prevent slipping of the keg on 
smooth surfaces such as hardwood floors, linoleum or 
tile. 

These casters should be installed on the front 

of the unit. IMPORTANT! Casters should be 
installed with wrench to prevent breakage!

3.

Once all 4 casters are attached return the kegerator to 

an upright position and allow to remain for at last 8-10 
hours (see 

Note 

above).

Copyright 2010 DTX International

UNPACKING YOUR KEGERATOR

REMOVING PACKAGING

Figure 1

Figure 2

Figure 3

KEGERATOR ASSEMBLY

CASTER ASSEMBLY

Figure 4

7

Summary of Contents for KEG6000

Page 1: ...KEGERATOR BEER KEG REFRIGERATOR 6 CU FT Copyright 2010 DTX International OPERATING MANUAL MODELS KEG6000 KEG6000B...

Page 2: ...the polarized plug by modifying the plug in any way All Great Northern Popcorn Company kegerators are warrantied against defects in material and workmanship for a period of one year for residential an...

Page 3: ...trical shock or fire MAKE SURE that your unit is properly grounded NEVER TAMPER WITH REMOVE OR CUT THE GROUNDING PIN The wall outlet used with this kegerator MUST be properly grounded If you do not ha...

Page 4: ...space 70 degrees F and 2 chain containers upright to avoid tipping or knocking Always wear gloves and safety glasses when around chemicals 4 Review and follow instructions for changing CO cylinders N...

Page 5: ...UAL GAUGE REGULATOR F CASTERS AND WASHERS G BEER TOWER PLUG H BEER TOWER SPIGOT HANDLE I GUARDRAIL J EXTRA WASHERS BEER CHOKE FLOAT ALLEN WRENCH CO LINE WASHERS 2 K KEG COUPLER L BEER TOWER M BEER LIN...

Page 6: ...KEGERATOR FLOW AND PARTS Copyright 2010 DTX International 6 SAVE THESE INSTRUCTIONS...

Page 7: ...ettle after shipping plug in the unit To assemble as a kegerator follow the rest of the assembly steps in this manual 4 Remove shelves shelf rack and packaged parts from the kegerator cabinet Unpack t...

Page 8: ...or 3 Feed first the beer line Figure B then the base of the tower into the hole making sure that the notches are aligned properly 4 Slide tower down and twist Figure C until it is secure no screws or...

Page 9: ...on dioxide is a potentially dangerous gas Canisters or cylinders are under pressure and proper handling is essential for safety ALWAYS HANDLE WITH CARE SPECIAL PRECAUTIONS Ensure that the safety devic...

Page 10: ...rs that are attached to the wrench and install as shown 6 Next attach the CO line to the regulator as shown in Figure M At this point 2 perform the following checks a Make sure that the red lever on t...

Page 11: ...oupler keg connection 3 Insert the CO line s black rubber washer into the coupler s side most 2 connector for the CO line there are two of these included in your packag 2 ing along with the other extr...

Page 12: ...both lines firmly connected to the keg coupler finalize the connection by pulling the black tap handle out Figure X and pushing down until it clicks securely Figure Y There will be an audible click s...

Page 13: ...ng the keg If your beer is running too slowly adjust the pressure on the regulator judiciously DO NOT EXCEED 12 PSI Condensation on the spigot or tap is normal It may take as much as 7 8 glasses of be...

Page 14: ...and twist dispenser faucet carefully off the top of the kegerator 4 Set the dispenser handle to the open or down position before flushing then position the faucet over a sink and hold the beer line un...

Page 15: ...Click below to find more Mipaper at www lcis com tw Mipaper at www lcis com tw...

Reviews: