GAS HOOK UP
5. When connecting regulator assembly to
the valve, hand tighten the quick
coupling nut clockwise to a complete
stop. Do not use a wrench to tighten.
Use of a wrench may damage the quick
coupling nut and result in a hazardous
condition.
6. Open the tank valve fully
(counterclockwise). Use a soapy water
solution to check all connections for
leaks before attempting to light the grill,
see below. If a leak is found, turn the
tank valve off and do not use the grill
until a local L.P. gas dealer can make
repairs.
To disconnect L.P. gas cylinder:
1. Turn the burner valves off.
2. Turn the tank valve off fully (turn
clockwise to stop).
3. Detach the regulator assembly from the
tank valve by turning the quick coupling
nut counterclockwise.
INSTALLER FINAL CHECK LIST
9
Specified clearance maintained
24”(61cm) from combustibles.
9
All internal packaging removed.
9
Knobs turn freely.
9
Burners are tight and sitting properly
on orifices.
9
Pressure regulator connected and set.
Gas connections to grill using hose &
regulator assembly provided (pre-set
for 11.0” water column).
9
Unit tested and free of leaks.
9
User informed of gas supply shut off
valve location
USER, PLEASE RETAIN THESE
INSTRUCTIONS FOR FUTURE
REFERENCE.
PROPANE CYLINDER CAUTIONS
a) Do Not store a spare LP-gas
cylinder under or near this
appliance.
b) NEVER fill the cylinder beyond 80
percent full.
c) If the information in “a” and “b” is
not followed exactly, a fire causing
death or serious injury may occur.
12
Section Three
Section Four