GAS REQUIREMENTS
Installation of the Nature Gas
The Nature Gas regulator has been factory installed. Attach the PVC Gas Hose to the regulator
(See drawing below).
Connect the other end of the PVC Gas Hose to the house gas line using the quick-connect fitting.
Liquid Propane (LP) Tank Installation
If grill is operated using L.P. (Liquid Propane) located the brass 3/8” flared fitting coming out of
the underside of the grill and attach the gas hose assembly provided with the grill. Attach the
other end of the gas hose assembly to a standard QCC-1 (screw- on) 20 lb. L.P. cylinder.
The L.P. cylinder must be provided with a shutoff valve terminating in an L.P gas supply
cylinder outlet specified, as applicable, for connection NO. 510 in the standard for compressed
gas cylinder valve outlet and inlet connection ANSI/CGA-V-1.
The L.P. gas supply cylinder must be constructed and marked in accordance with the
specification for L.P. gas cylinders of the U.S. Department of Transpiration (DOT) or the
National Standard of Canada, CAN/CAS-B339, “Cylinders, Spheres and Tubes for the
Transportation of Dangerous Goods.”
NEVER ATTACH AN UNREGULATED GAS LINE TO THE GRILL.
8
Section Two