(4)
Wire feed speed potentiometer
1 - 15 m/min (39.4 - 590.6 ipm.) for wire threading and wire retraction
(5)
Torque potentiometer
10 - 100% (10% = 5 N, 100% = 50 N)
Factory setting: 40%
(6)
Opening for optional sash lock
(7)
Control panel
(8)
Robot control connection
(option)
(9)
Mains switch
(10)
Mains cable connection
(11)
Strain-relief device for the mains cable
(12)
Blanking cover for optional component
(13)
Wire infeed/outfeed tube
Wire infeed (underside)
Wire outfeed (top)
(14)
M20 thread
for connecting QuickConnect option
Control panel
Mode
Start
(1)
(2) (3)
(4)
(5)
(6)
Gas test/wire threading control panel
No.
Function
(1)
Mains supply LED
(2)
Torque mode LED
(3)
Wire threading mode LED
The LEDs are dual LEDs, which light up
green and red or can flash.
Functional description of the LEDs accord-
ing to the sections
"LED indicators" on page
and
"LED indicators in the event of a fault" on
page
No.
Function
(4)
Mode / Start button
-
for switching between torque mode
and wire threading mode
-
for starting torque mode
23