Care, maintenance and disposal
General
Under normal operating conditions, the welding system requires only a minimum of care
and maintenance. However, it is vital to observe some important points to ensure the
welding system remains in a usable condition for many years.
Safety
WARNING!
An electric shock can be fatal.
Before opening the device
▶
Turn the mains switch to the "O" position
▶
Unplug the device from the mains
▶
Ensure the device cannot be switched back on
▶
Using a suitable measuring instrument, check to make sure that electrically charged
components (e.g. capacitors) have been discharged
WARNING!
Work that is carried out incorrectly can cause serious injury and damage.
▶
The following activities must only be carried out by trained and qualified personnel.
▶
All instructions in the section headed "Safety rules" must be observed.
Every start-up
-
Check torch hosepack, interconnecting hosepack and ground earth connection for
signs of damage. Replace any damaged components
-
Check feed rollers and inner liners for signs of damage. Replace any damaged com-
ponents
-
Check contact pressure of feed rollers and adjust if necessary
-
Check that all screw connections between the robot, wire-feed unit mount and wire-
feed unit are secure
-
Check all screw joints on system components and associated mounts for tightness
Every 6 months
NOTE!
Risk of damage to electronic components.
Do not bring the air nozzle too close to electronic components.
-
Remove the cover from the device and clean the inside with dry reduced com-
pressed air
Disposal
Dispose of in accordance with the applicable national and local regulations.
34
Summary of Contents for WF 25i REEL R /SA/2R/G/W
Page 2: ......
Page 19: ...Wear eye protection 19 EN...
Page 27: ...3 4 5 27 EN...
Page 30: ...AlMg 3 5 Al AlSi 2 4 Tubular cored elec trodes 3 5 30...