68
t-S
Time starting - starting current time
Unit
s
Setting range
OFF/0.01 - 9.9
Factory settings
OFF
The starting current time t-S specifies the duration of the starting current phase Is.
IMPORTANT!
The t-S setup parameter only applies to 2-step mode. In 4-step mode, the
duration of the starting current phase Is is controlled using the torch trigger.
t-E
Time end - end current time
Unit
s
Setting range
OFF/0.01 - 9.9
Factory settings
OFF
The end current time t-E specifies the duration of the end current phase IE.
IMPORTANT!
The setup parameter t-E only applies to 2-step mode. In 4-step mode, the
duration of the end current phase IE is controlled using the torch trigger (see "TIG oper-
ating modes").
FAC
Factory - for resetting the welding system
Press and hold the Mode button for 2 s to reset the system to the factory settings. When
the digital display shows "PrG", the welding system has been reset.
IMPORTANT!
When the welding system is reset, all the personal settings in the Setup
menu are lost. Welding parameter settings in Setup menu: level 2 are not deleted.
2nd
Setup menu: level 2: second level of the setup menu
Summary of Contents for TransTig 1750 Puls
Page 2: ...0 ...
Page 4: ...2 ...
Page 8: ...6 ...
Page 22: ...20 ...
Page 23: ...General information ...
Page 24: ......
Page 26: ...24 ...
Page 27: ...Control elements and connections ...
Page 28: ......
Page 36: ...34 ...
Page 37: ...Installation and commissioning ...
Page 38: ......
Page 44: ...42 ...
Page 45: ...Welding ...
Page 46: ......
Page 50: ...48 I t I1 GPr IS tdown IE G L G H I1 I2 tup tE tS ...
Page 63: ...Setup settings ...
Page 64: ......
Page 77: ...Troubleshooting and maintenance ...
Page 78: ......
Page 83: ...Appendix ...
Page 84: ......
Page 86: ...84 Spare parts list ...