66
TIG setup menu
Accessing the
TIG setup menu
Changing weld-
ing parameters
Exiting the TIG
setup menu
Welding parame-
ters in the TIG set-
up menu
Press the Mode button to select 2-step mode or 4-step mode
Press and hold the Mode button
Press the Parameter Selection button (right)
The power source is now in the TIG setup menu. The last welding pa-
rameter selected is displayed.
1
2
3
Use the left or right Parameter Selection button to select the param-
eter that you want to change
Use the adjusting dial to change the parameter value
1
2
Press the Mode button
1
SPt
Spot welding time
Unit
s
Setting range
OFF / 0.05 - 25.0
Factory settings
OFF
If a value has been set for the SPt setup parameter, the operating mode 2-step mode will
have the function of the spot welding mode.
The special spot welding indicator on the control panel remains lit as long as a value has
been specified for the spot welding time.
tAC
Tacking function when TIG DC welding is selected: Duration of the pulsed welding current
at the start of tacking
Unit
s
Setting range
OFF / 0.1 - 9.9 / ON
Summary of Contents for TransTig 1750 Puls
Page 2: ...0 ...
Page 4: ...2 ...
Page 8: ...6 ...
Page 22: ...20 ...
Page 23: ...General information ...
Page 24: ......
Page 26: ...24 ...
Page 27: ...Control elements and connections ...
Page 28: ......
Page 36: ...34 ...
Page 37: ...Installation and commissioning ...
Page 38: ......
Page 44: ...42 ...
Page 45: ...Welding ...
Page 46: ......
Page 50: ...48 I t I1 GPr IS tdown IE G L G H I1 I2 tup tE tS ...
Page 63: ...Setup settings ...
Page 64: ......
Page 77: ...Troubleshooting and maintenance ...
Page 78: ......
Page 83: ...Appendix ...
Page 84: ......
Page 86: ...84 Spare parts list ...