38
Replacing String Fuses
Replacing
String Fuses
Interrupt the connection to the AC supply lines using the inverter AC
disconnector
WARNING!
Operating the equipment incorrectly can cause
serious injury and damage. The following activities must only
be carried out by trained and qualified personnel. Follow the
safety rules in these operating instructions.
Safety
Preparation
WARNING!
An electrical shock can be fatal. Danger from DC
voltage from solar modules.
-
Make sure that the input and output sides in front of the
device are not charged before conducting maintenance
work.
-
Never remove a fuse while it is under load.
1
2
Attach a clearly legible and easy-to-understand warning sign to pre-
vent anyone from switching it back on or from reconnecting any open
or interrupted connections
3
Check to make sure that solar module strings are deenergized
Short circuit solar module strings
5
Remove the cover
6
Test the fuse holder at the terminals for continuity
6
NOTE
Only use fuses for solar modules that meet the proper
requirements for string fuses.
Fuse dimensions: Diameter 10 x 38 mm
When replacing string fuses, the protection against contact can remain in
the device.
For reasons of clarity, the protection against contact has been left out of
the following illustrations.
Summary of Contents for String Control 250/ 25 DCD DF
Page 2: ......
Page 4: ......
Page 50: ...40...
Page 54: ......
Page 98: ...40...
Page 102: ......
Page 149: ...ud_fr_st_et_01482 012007 ZH...
Page 150: ......
Page 151: ...ud_fr_se_sv_01483 012012 I ZH...
Page 152: ...ud_fr_se_sv_01483 012012 II...
Page 153: ...ud_fr_se_sv_01483 012012 III ZH...
Page 154: ...ud_fr_se_sv_01483 012012 IV...
Page 155: ...1 ZH...
Page 156: ...2...
Page 157: ...3 ZH...
Page 158: ...4...
Page 159: ...5 ZH...
Page 160: ...6...
Page 161: ...7 ZH 1 2 3 4 5 6 7 8 9 10 11 12 19 13 17 14 15 16 18 20 21 22 23 24 25 26 27 28 29 1XX 0XX...
Page 162: ...8...
Page 163: ...9 ZH...
Page 164: ...10...
Page 165: ...11 ZH 3 2 3 4 4 x 1 4 1 2 3 x 4 5 3 2 1 2 4 3 1 2 1 1 3 5 4...
Page 167: ...13 ZH 1 1 2 3...
Page 168: ...14...
Page 170: ...16 3 10mm 1 2 5 3 4 A B 2 5 10mm 1 2 4 3 A B 1 3 1 1 2 3 4...
Page 171: ...17 ZH 4 3 2 4 5 6 1 3 3 2 4 5 6 1 2 1 2 1 2 1 1 2 M12 M12 3 4 M12 M12...
Page 172: ...18...
Page 173: ...19 ZH...
Page 174: ...20...
Page 175: ...21 ZH 2 1 1 1 2 1 2 1 Strang...
Page 176: ...22...
Page 177: ...23 ZH Line ISDN OUT IN OUT IN OUT IN...
Page 178: ...24 4 2 1 3 3 1 3 DATCO M IN DATCO M O UT 2 2 IN OUT 1 2 1 3 1 2...
Page 179: ...25 ZH 3 10mm 1 2 2 1...
Page 180: ...26 5 1 4 4 3 6 5 OUT IN 2 1 IN OUT 12 V GND TX RX RX TX GND 12 V 12 V GND RX TX TX RX GND 12 V...
Page 181: ...27 ZH 1 2...
Page 182: ...28 1 2...
Page 183: ...29 ZH...
Page 184: ...30...
Page 185: ...31 ZH 6 1 5 1...
Page 186: ...32 1XX 0XX 0XX 1XX 0XX 1XX 0XX 1XX 0 1 0 3 7 0 2 3 1 2 3 1...
Page 187: ...33 ZH 1 4 3 3 4 2 1 1 OFF ON 1 1 1 1...
Page 188: ...34 1 2 3...
Page 189: ...35 ZH...
Page 190: ...36...
Page 191: ...37 ZH 1...
Page 192: ...38...
Page 193: ...39 ZH 1 1 1 2 2 2 1 2 1 2...
Page 194: ...40...