![Fronius RI FB PRO/i Operating Instructions Manual Download Page 25](http://html1.mh-extra.com/html/fronius/ri-fb-pro-i/ri-fb-pro-i_operating-instructions-manual_2339326025.webp)
Setting the Bus Module IP Address
Setting the Bus
Module IP Ad-
dress
You can set the bus module IP address
as follows:
1
.
Using the DIP switch in the inter-
face within the range defined by
192.168.0.xx
(xx = DIP switch setting = 1 to 63)
-
All positions are set to the
OFF position at the factory. In
this case, the IP address must
be set on the website of the
power source
2
.
On the website of the power
source (if all positions of the DIP
switch are set to the OFF position)
The IP address is set using DIP switch positions 1 to 6. The configuration is carri-
ed out in binary format. This results in a configuration range of 1 to 63 in decimal
format.
Example for setting the IP address of the bus module using the DIP switch in
the interface:
Dip switch
8
7
6
5
4
3
2
1
IP address
-
-
OFF
OFF
OFF
OFF
OFF
ON
1
-
-
OFF
OFF
OFF
OFF
ON
OFF
2
-
-
OFF
OFF
OFF
OFF
ON
ON
3
-
-
ON
ON
ON
ON
ON
OFF
62
-
-
ON
ON
ON
ON
ON
ON
63
Instructions for setting the IP address on the website of the power source:
Note down the IP address of the power source used:
1
On the power source control panel, select "Defaults"
2
On the power source control panel, select "System"
3
On the power source control panel, select "Information"
4
Note down the displayed IP address (example: 10.5.72.13)
Access website of the power source in the internet browser:
5
Connect the computer to the network of the power source
6
Enter the IP address of the power source in the search bar of the internet
browser and confirm
7
Enter the standard user name (admin) and password (admin)
-
The website of the power source is displayed
Set the bus module IP address:
8
On the power source website, select the "RI FB PRO/i" tab
25