General
Safety
WARNING!
Danger from incorrect operation and work that is not carried out properly.
This can result in serious personal injury and damage to property.
▶
All the work and functions described in this document must only be carried
out by technically trained and qualified personnel.
▶
Read and understand this document in full.
▶
Read and understand all safety rules and user documentation for this equip-
ment and all system components.
Connections and
Displays
1
2
3
4
5
6
7
8
RJ45 connection
1
TX+
2
TX-
3
RX+
6
RX-
4,5,7,
8
Not normally used; to ensu-
re signal completeness, the-
se pins must be intercon-
nected and, after passing
through a filter circuit, must
terminate at the ground
conductor (PE).
(1)
(1) LED MS - Module status
Off:
No supply voltage
Lights up green:
Controlled by a master
Flashes green (once):
Master not configured or master idle
Lights up red:
Major error (exception state, serious
fault, ...)
Flashes red:
Correctable error
22