The ground conductor leakage current must not exceed the limit value of 3.5 mA during
this measurement (direct or differential current method**).
**) These requirements comply with DIN VDE 0701-0702 and ÖVE/ÖNORM E8701-1. Also
refer to the applicable requirements and standards in your country.
Contact Current
-
Only Perform The Measurement If A Ground Conductor Current Measurement Has
Been Carried Out Successfully
-
As Before, The Device Must Be Switched On.
The Measurement Is Taken Between A Grounded Point And The Touchable, Conductive
Part That Is Not Connected To The Ground Conductor.
The Contact Current Must Not Exceed 0.5 Ma *).
1 Measuring Device
2 Inverter
6.2 Touchable, Conductive Part Not Connected To
The Ground Conductor
8 Isolated Setup Of Test Piece
9 Measuring Line
Ri 1 - 2 K
Touchable, Conductive Parts Not Connected To The
Ground Conductor
*) These Requirements Comply With Din Vde 0701-0702 And Öve/önorm E8701-1. Also
Refer To The Applicable Requirements And Standards In Your Country.
PE
mA
L1
1
2
9
N
PE
L1
N
9
8
6.2
Ri
1-2k
Ω
Summary of Contents for Primo 3.0-1
Page 2: ...2 ...
Page 5: ...Allgemeine Informationen ...
Page 6: ......
Page 13: ...Fehler Suchhilfe ...
Page 14: ......
Page 32: ...32 ...
Page 33: ...Komponenten austauschen ...
Page 34: ......
Page 54: ...54 DC Trenner auf ON stellen 6 ...
Page 65: ...Sicherheitstechnische Überprüfung ...
Page 66: ......
Page 78: ...78 ...
Page 81: ...General information ...
Page 82: ......
Page 89: ...Error location aid ...
Page 90: ......
Page 108: ...108 ...
Page 109: ...Changing components ...
Page 110: ......
Page 130: ...130 Set the DC disconnector to ON 6 ...
Page 141: ...Safety Inspections ...
Page 142: ......
Page 154: ...154 ...
Page 155: ...Appendix ...
Page 158: ...158 ...
Page 159: ...159 ...