![Fronius Primo 10.0-1 208-240 Installation Instructions Manual Download Page 11](http://html1.mh-extra.com/html/fronius/primo-10-0-1-208-240/primo-10-0-1-208-240_installation-instructions-manual_2339190011.webp)
Do not install the inverter overhanging with the connections
downwards.
Do not install the inverter on the ceiling.
Selecting a loca-
tion – general in-
formation for
Fronius Primo
3.8 - 8.2
Please observe the following criteria when choosing a location for the inverter:
Only install on a solid, non-flammable surface
Max. ambient temperatures:
-40°F to +131°F
(-40°C to +55°C)
Relative humidity:
0 - 100%
The air flow direction within
the inverter is from left and
right to top (cold air intake
on the left and right, hot air
outflow at the top).
The waste air can reach a
temperature of 70°C.
When installing the inverter in a switch cabinet or similar closed environment, it
is necessary to make sure that the hot air that develops will be dissipated by
forced-air ventilation
If you wish to install the inverter on the outer walls of a cattle shed, it is import-
ant to maintain a minimum clearance of 6 ft. 7 in. (2 m) between all sides of the
inverter and air vents and other openings.
The place of installation should not be exposed to ammonia, corrosive gases,
salts, or acids.
Selecting a loca-
tion – general in-
formation for
Fronius Primo
10.0 - 15.0
Please observe the following criteria when choosing a location for the inverter:
Only install on a solid, non-flammable surface
11
EN-US
Summary of Contents for Primo 10.0-1 208-240
Page 2: ......
Page 13: ...Preparation 13...
Page 14: ...14...
Page 21: ...AC 21...
Page 22: ...22...
Page 31: ...DC 31...
Page 32: ...32...
Page 42: ...2 2 1 max 0 28 in 7 mm 8 Fit the padlock to the anti theft device 42...
Page 50: ...50...
Page 51: ...51 EN US...
Page 52: ......